Search
Now showing items 21-30 of 520
Experimental determination of J-integral at elevated temperatures
(17th European Conference on Fracture 2008: Multilevel Approach to Fracture of Materials, Components, 2008)
In past two decades, the development of 9-12% Cr creep-resistant steel for critical components in coal-fired power stations that can withstand higher temperatures and pressures has been intensified in order to increase ...
The effect of annealing temperatures and cooling rates on microstructure and mechanical properties of investment cast Ti-6Al-4V alloy
(Elsevier Sci Ltd, Oxford, 2006)
Production of investment castings of titanium alloys was considerably increased during last years due to the significant cost savings compared to complicated machined parts. However, the disadvantage of as-cast titanium ...
Structural integrity assessment by local approach to fracture
(Kluwer Academic Publishers, 2006)
Modelling of ductile fracture initiation in strength mismatched welded joint
(Pergamon-Elsevier Science Ltd, Oxford, 2008)
In this paper, the effect of strength mismatch and width of the welded joints oil the stress-strain distribution in the crack tip region has been discussed. The single-edge notched bend (SENB) specimens (precrack length ...
Evaluation of damage of steam pipeline steel using local approach to fracture
(American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP, 2008)
In the paper, the level of damage of steam pipeline steel after about 100,000 hours at 540°C (1004 °F) under pressure of 42 bars (609 PSI) is analyzed. Material degradation is estimated using a combined experimental and ...
Welded penstock, produced of high-strength steel and application of fracture mechanics parameters to structural integrity assessment
(Springer, Dordrecht, 2008)
Application of high-strength steel for welded penstock increased the probability of crack-like defects and in welded joint. Structural integrity assessment procedure is presented and applied to welded penstock produced of ...
Analysis of fouling factor in district heating heat exchangers with parallel helical tube coils
(Pergamon-Elsevier Science Ltd, Oxford, 2013)
This paper presents the results of measurements of thermal performance of 8 heat exchangers with parallel helical coils. Measurements were conducted in substations in 2 district heating systems in Serbia: Belgrade and ...
Simultaneous consideration of contingency factors and quality management: An empirical study of Serbian companies
(Academic Journals, Victoria Island, 2011)
The aim of the present paper is to answer whether the QM concept is universal or context-dependent, organic or mechanistic, and theoretical or practical in its essence. The study examines the impact of contingency factors ...
Analysis of local shrinkage patterns of self-adhering and flowable composites using 3D digital image correlation
(Quintessence International, 2011)
Objective: To analyze local shrinkage patterns in terms of surface shrinkage strains and z-axis displacements in a novel self-adhering composite and a conventional flowable composite using three-dimensional digital image ...
Groundwater heat pump selection for high temperature heating retrofit
(Elsevier Science Sa, Lausanne, 2012)
Retrofitting of fossil fuel powered hot water radiator heating systems of the existing buildings by groundwater heat pumps can provide significant energy savings followed by economic and environmental benefits. The paper ...