Приказ основних података о документу

Integrity assessment of hot-water boiler tubing system exposed to corrosion

dc.creatorŠijački-Žeravčić, Vera
dc.creatorBakić, Gordana
dc.creatorĐukić, Miloš
dc.creatorAnđelić, Biljana
dc.creatorRajičić, Bratislav
dc.creatorAsul, Jasmina
dc.date.accessioned2022-09-19T16:17:49Z
dc.date.available2022-09-19T16:17:49Z
dc.date.issued2009
dc.identifier.issn0350-218X
dc.identifier.urihttps://machinery.mas.bg.ac.rs/handle/123456789/917
dc.description.abstractU cilju izvođenja validne procene integriteta komponenti ugrađenih u industrijska energetska postrojenja neophodno je primeniti metodološki pristup koji obuhvata prikupljanje, sistematizaciju i analizu podataka iz eksploatacione istorije, propisivanje programa ispitivanja stanja materijala metodama sa i bez razaranja, kao i odgovarajućih kriterijuma prihvatljivosti. U radu je dat primer procene integriteta cevnog sistema vrelovodnog kotla jednog domaćeg postrojenja izloženog koroziji na osnovu podataka iz eksploatacione istorije, rezultata ranijih ispitivanja, kao i na osnovu poređenja dobijenih rezultata ispitivanja sa usvojenim kriterijumima prihvatljivosti. Procena integriteta kritičnih komponenti predstavlja podlogu za definisanje predloga o parcijalnoj zameni kotlovskih cevi, kao i niza korektivno - preventivnih koje imaju za cilj prevenciju pojave razaranja kao i obezbeđivanje visoke pouzdanosti u radu.sr
dc.description.abstractIn the aim of valid assessment of components integrity built-in industrial plants it was necessary to apply methodological approach, which includes: plant service history data acquisition, assortment and analysis, defining a programme for non-destructive and destructive inspection of material, and formulating of acceptance criteria. This paper present an example of integrity assessment of hot-water boiler tubing system exposed to corrosion based on boiler service history, previous test results and comparison of new results to adopted acceptance criteria. Integrity assessment of critical components represent background for defining of boiler tube partial replacement proposal, and also for defining of corrective and preventive maintenance measures. .en
dc.publisherUniverzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd i Društvo termičara Srbije, Beograd
dc.rightsopenAccess
dc.sourceTermotehnika
dc.subjectvrelovodni kotaosr
dc.subjectprocena integritetasr
dc.subjectkorozijasr
dc.subjectkorektivno-preventivne meresr
dc.subjectcevni sistemsr
dc.subjectintegrity assessmenten
dc.subjecthot-water boileren
dc.subjectcorrosionen
dc.subjectcorrective and preventive measuresen
dc.subjectboiler tubing systemen
dc.titleOcena integriteta cevnog sistema vrelovodnog kotla izloženog korozijisr
dc.titleIntegrity assessment of hot-water boiler tubing system exposed to corrosionen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage110
dc.citation.issue1
dc.citation.other35(1): 95-110
dc.citation.rankM51
dc.citation.spage95
dc.citation.volume35