Heat transfer rate of direct-contact condensation on baffle trays
Само за регистроване кориснике
2008
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The paper deals with the experimentally obtained results of the direct-contact condensation of steam in contact with water in cascade column. Baffle trays were used to obtain contact between water and steam in DN 300 column at atmospheric pressure. Testing of Chernobilski equation showed poor correlation compared to the experimental results so we have found the following form of heat transfer rate Nu = 5.8 . 10(-6) . Re(5/3) . Pr(1/3) . Fr(-2/3) which could be recommended for heat transfer calculations for this kind of apparatuses.
Кључне речи:
Phase change / Number of transfer units / Heat transfer / Convective transport / Condensation / Baffle trayИзвор:
International Journal of Heat and Mass Transfer, 2008, 51, 25-26, 5772-5776Издавач:
- Pergamon-Elsevier Science Ltd, Oxford
DOI: 10.1016/j.ijheatmasstransfer.2008.05.017
ISSN: 0017-9310
WoS: 000261628800003
Scopus: 2-s2.0-55649088010
Колекције
Институција/група
Mašinski fakultetTY - JOUR AU - Genić, Srbislav AU - Jaćimović, Branislav M. AU - Vladić, Ljubiša PY - 2008 UR - https://machinery.mas.bg.ac.rs/handle/123456789/858 AB - The paper deals with the experimentally obtained results of the direct-contact condensation of steam in contact with water in cascade column. Baffle trays were used to obtain contact between water and steam in DN 300 column at atmospheric pressure. Testing of Chernobilski equation showed poor correlation compared to the experimental results so we have found the following form of heat transfer rate Nu = 5.8 . 10(-6) . Re(5/3) . Pr(1/3) . Fr(-2/3) which could be recommended for heat transfer calculations for this kind of apparatuses. PB - Pergamon-Elsevier Science Ltd, Oxford T2 - International Journal of Heat and Mass Transfer T1 - Heat transfer rate of direct-contact condensation on baffle trays EP - 5776 IS - 25-26 SP - 5772 VL - 51 DO - 10.1016/j.ijheatmasstransfer.2008.05.017 ER -
@article{ author = "Genić, Srbislav and Jaćimović, Branislav M. and Vladić, Ljubiša", year = "2008", abstract = "The paper deals with the experimentally obtained results of the direct-contact condensation of steam in contact with water in cascade column. Baffle trays were used to obtain contact between water and steam in DN 300 column at atmospheric pressure. Testing of Chernobilski equation showed poor correlation compared to the experimental results so we have found the following form of heat transfer rate Nu = 5.8 . 10(-6) . Re(5/3) . Pr(1/3) . Fr(-2/3) which could be recommended for heat transfer calculations for this kind of apparatuses.", publisher = "Pergamon-Elsevier Science Ltd, Oxford", journal = "International Journal of Heat and Mass Transfer", title = "Heat transfer rate of direct-contact condensation on baffle trays", pages = "5776-5772", number = "25-26", volume = "51", doi = "10.1016/j.ijheatmasstransfer.2008.05.017" }
Genić, S., Jaćimović, B. M.,& Vladić, L.. (2008). Heat transfer rate of direct-contact condensation on baffle trays. in International Journal of Heat and Mass Transfer Pergamon-Elsevier Science Ltd, Oxford., 51(25-26), 5772-5776. https://doi.org/10.1016/j.ijheatmasstransfer.2008.05.017
Genić S, Jaćimović BM, Vladić L. Heat transfer rate of direct-contact condensation on baffle trays. in International Journal of Heat and Mass Transfer. 2008;51(25-26):5772-5776. doi:10.1016/j.ijheatmasstransfer.2008.05.017 .
Genić, Srbislav, Jaćimović, Branislav M., Vladić, Ljubiša, "Heat transfer rate of direct-contact condensation on baffle trays" in International Journal of Heat and Mass Transfer, 51, no. 25-26 (2008):5772-5776, https://doi.org/10.1016/j.ijheatmasstransfer.2008.05.017 . .