dc.description.abstractThis study aimed to (1) comparatively analyze properties of Sr- and Mg-substituted hydroxyapatite (HAP)-based dental inserts; (2) evaluate insert bonding to restorative materials, and (3) evaluate the effect of doped HAP inserts on fracture resistance (FR) of human molars with large occlusal restorations. By ion-doping with Sr or Mg, 3 insert types were obtained and characterized using XRD, SEM, Vickers hardness and fracture toughness. Shear bond strength (SBS) was determined between acid etched or unetched inserts and following materials: Maxcem cement (Kerr); Filtek Z250 (3M) bonded with Single Bond Universal (SBU; 3M) or Clearfil Universal (Cf; Kuraray). Modified Class I cavities were prepared in 16 intact molars and restored using insert + composite or composite only (control) (n = 8/group). FR of restored molars was determined by static load until fracture upon thermal cycling. Fracture toughness was similar between Sr/Mg-doped inserts (0.94–1.04 MPam−1/2 p = .429). Mg-doped inserts showed greater hardness (range 4.78–5.15 GPa) than Sr6 inserts (3.74 ± 0.31 GPa; p < .05). SBS for SBU and Cf adhesives (range 7.19–15.93 MPa) was higher than for Maxcem (range 3.07–5.95 MPa) (p < .05). There was no significant difference in FR between molars restored with insert-containing and control restorations (3.00 ± 0.30 kN and 3.22 ± 0.42 kN, respectively; p > .05). HAP-based inserts doped with Mg/Sr had different composition and mechanical properties. Adhesive bonding to inserts resulted in greater bond strength than cementation, which may be improved by insert acid-etching. Ion-doped HAP inserts did not affect FR of restored molars. In conclusion, HAP-based dental inserts may potentially replace dentin in large cavities, without affecting fracture resistance of restored teeth.sr
dc.language.isoensr
dc.publisherWileysr
dc.rightsrestrictedAccesssr
dc.sourceJurnal of biomedical materials research Part B: Applied Biomaterialssr
dc.subjectInženjerstvo materijalasr
dc.subjectstomatološki materijalisr
dc.titleHydroxyapatite-based dental inserts: Microstructure, mechanical properties, bonding efficiency and fracture resistance of molars with occlusal restorationssr
dc.typearticlesr
dc.rights.licenseARRsr
dc.citation.issue1
dc.citation.rankM22
dc.citation.volume112
dc.identifier.doi10.1002/jbm.b.35331