Приказ основних података о документу
Analiza rezultata ispitivanja vrelovodnog kotla kao podloga za ocenu njegovog integriteta
Analysis of test results of hot-water boiler as a basis for its integrity assessment
dc.creator | Šijački-Žeravčić, Vera | |
dc.creator | Bakić, Gordana | |
dc.creator | Đukić, Miloš | |
dc.creator | Anđelić, Biljana | |
dc.date.accessioned | 2022-09-19T16:05:41Z | |
dc.date.available | 2022-09-19T16:05:41Z | |
dc.date.issued | 2007 | |
dc.identifier.issn | 1451-3749 | |
dc.identifier.uri | https://machinery.mas.bg.ac.rs/handle/123456789/743 | |
dc.description.abstract | Procena eksploatacijske raspoloživosti i integriteta materijala termoenergetske opreme zahteva primenu metodološkog pristupa koji obuhvata prikupljanje i analizu podataka iz eksploatacije, definisanje programa ispitivanja stanja materijala metodama bez razaranja i razaranjem i propisivanje kriterijuma prihvatljivosti. Na osnovu podataka iz eksploatacije kotlovskog postrojenja, rezultata ranijih ispitivanja, kao i na osnovu poređenja novih rezultata ispitivanja sa kriterijumima prihvatljivosti izvršena je procenu integriteta vrelovodnog kotla u toplani "Mirijevo" u sastavu JKP "Beogradske elektrane". Nakon procene integriteta ugroženih delova cevnog sistema kotla definisan je predlog o parcijalnoj zameni ekranskih cevi, kao i niz preporuka za eksploataciju radi prevencije otkaza ekranskih cevi. | sr |
dc.description.abstract | Assessment of service availability and integrity of power plant component materials requires the use of methodological approach, that includes service history data acquisition and analysis; defining a programme for material state nondestructive and destructive testing; and formulating acceptance criteria. Data based on boiler service history and on previous test results comparing the new results to adopted acceptance criteria served as a basis for integrity assessment of hot-water boiler at plant "Mirijevo", belonging to JKP "Beogradske elektrane". Following the integrity assessment of critical boiler piping system parts, a proposal is defined for partial replacement of boiler wall tubes and a sequence of service recommendations how to prevent appearance of wall tubing damage is also given. | en |
dc.publisher | Institut za ispitivanje materijala, Beograd | |
dc.rights | openAccess | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Integritet i vek konstrukcija | |
dc.subject | vrelovodni kotao | sr |
dc.subject | procena integriteta | sr |
dc.subject | korektivno-preventivne mere | sr |
dc.subject | ispitivanja sa razaranjem | sr |
dc.subject | ispitivanja bez razaranja | sr |
dc.subject | non-destructive tests | en |
dc.subject | integrity assessment | en |
dc.subject | hot-water boiler | en |
dc.subject | destructive tests | en |
dc.subject | corrective and preventive measures | en |
dc.title | Analiza rezultata ispitivanja vrelovodnog kotla kao podloga za ocenu njegovog integriteta | sr |
dc.title | Analysis of test results of hot-water boiler as a basis for its integrity assessment | en |
dc.type | article | |
dc.rights.license | BY-NC-ND | |
dc.citation.epage | 140 | |
dc.citation.issue | 2 | |
dc.citation.other | 7(2): 133-140 | |
dc.citation.spage | 133 | |
dc.citation.volume | 7 | |
dc.identifier.fulltext | http://machinery.mas.bg.ac.rs/bitstream/id/2628/740.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_machinery_743 | |
dc.type.version | publishedVersion |