Experimental setup for determining strain in dental composite veneers subjected to compressive load
2018
Аутори
Milošević, MilošCabunac, Jovan
Milovanović, Aleksa
Mitrović, Nenad
Mladenović, Goran
Miletić, Vesna
Конференцијски прилог (Објављена верзија)
,
Society for Structural Integrity and Life – Prof. Dr Stojan Sedmak (DIVK), Belgrade
Метаподаци
Приказ свих података о документуАпстракт
Veneers are thin dental restorations which cover vestibular, incisal and proximal teeth surfaces. Depending on the design of the preparation, proximal extension of the veneer could be up to the contact point or could cover the entire proximal surfaces of the teeth. This paper shows development of the experimental setup for determining the strain field and failure force of direct composite veneers in upper and lower anterior teeth, subjected to compressive load up to the point of fracture. Extracted teeth were prepared using the turbine diamond conical burrs with a rounded tip of 1.6 mm in diameter and 2° conicity (Burr 6844-Komet Dental, Lemgo, Germany). The preparation was standardized so that the dental tissue was removed 0.8 to 1 mm vestibularly, 0.5 to 0.8 mm proximally and 2 mm incisally. The veneers were made of composite material (nanocomposite Geanial-GC Corp., Tokyo, Japan) using the direct layering technique. Bonding ... between the material and dental tissue was achieved using an adhesive agent (G bond-GC Corp., Tokyo, Japan).
The prepared specimens, which consisted of a tooth-adhesive-composite system, were immersed in acrylic for easier
positioning into the tensile testing machine (Tinius Olsen HlOKS). Contactless optical 3D system ARAMIS 2.0 was used for measuring strain in the veneers. In order to simulate the effect of masticatory forces, the prepared specimens were positioned under a 135 degree angle relative to the applied force.
This experimental setup will enable analysis of stress and strain of the tooth-adhesive-veneer system, based on clinically relevant parameters (design of the preparation, material characteristics and angle of the applied force).
Кључне речи:
dental / composite veneers / strain field / failure force / optical 3D measurement / ARAMISИзвор:
22nd European Conference on Fracture - ECF22, 2018, 99-99Издавач:
- Society for Structural Integrity and Life – Prof. Dr Stojan Sedmak (DIVK), Belgrade
Колекције
Институција/група
Mašinski fakultetTY - CONF AU - Milošević, Miloš AU - Cabunac, Jovan AU - Milovanović, Aleksa AU - Mitrović, Nenad AU - Mladenović, Goran AU - Miletić, Vesna PY - 2018 UR - https://machinery.mas.bg.ac.rs/handle/123456789/6938 AB - Veneers are thin dental restorations which cover vestibular, incisal and proximal teeth surfaces. Depending on the design of the preparation, proximal extension of the veneer could be up to the contact point or could cover the entire proximal surfaces of the teeth. This paper shows development of the experimental setup for determining the strain field and failure force of direct composite veneers in upper and lower anterior teeth, subjected to compressive load up to the point of fracture. Extracted teeth were prepared using the turbine diamond conical burrs with a rounded tip of 1.6 mm in diameter and 2° conicity (Burr 6844-Komet Dental, Lemgo, Germany). The preparation was standardized so that the dental tissue was removed 0.8 to 1 mm vestibularly, 0.5 to 0.8 mm proximally and 2 mm incisally. The veneers were made of composite material (nanocomposite Geanial-GC Corp., Tokyo, Japan) using the direct layering technique. Bonding between the material and dental tissue was achieved using an adhesive agent (G bond-GC Corp., Tokyo, Japan). The prepared specimens, which consisted of a tooth-adhesive-composite system, were immersed in acrylic for easier positioning into the tensile testing machine (Tinius Olsen HlOKS). Contactless optical 3D system ARAMIS 2.0 was used for measuring strain in the veneers. In order to simulate the effect of masticatory forces, the prepared specimens were positioned under a 135 degree angle relative to the applied force. This experimental setup will enable analysis of stress and strain of the tooth-adhesive-veneer system, based on clinically relevant parameters (design of the preparation, material characteristics and angle of the applied force). PB - Society for Structural Integrity and Life – Prof. Dr Stojan Sedmak (DIVK), Belgrade C3 - 22nd European Conference on Fracture - ECF22 T1 - Experimental setup for determining strain in dental composite veneers subjected to compressive load EP - 99 SP - 99 UR - https://hdl.handle.net/21.15107/rcub_machinery_6938 ER -
@conference{ author = "Milošević, Miloš and Cabunac, Jovan and Milovanović, Aleksa and Mitrović, Nenad and Mladenović, Goran and Miletić, Vesna", year = "2018", abstract = "Veneers are thin dental restorations which cover vestibular, incisal and proximal teeth surfaces. Depending on the design of the preparation, proximal extension of the veneer could be up to the contact point or could cover the entire proximal surfaces of the teeth. This paper shows development of the experimental setup for determining the strain field and failure force of direct composite veneers in upper and lower anterior teeth, subjected to compressive load up to the point of fracture. Extracted teeth were prepared using the turbine diamond conical burrs with a rounded tip of 1.6 mm in diameter and 2° conicity (Burr 6844-Komet Dental, Lemgo, Germany). The preparation was standardized so that the dental tissue was removed 0.8 to 1 mm vestibularly, 0.5 to 0.8 mm proximally and 2 mm incisally. The veneers were made of composite material (nanocomposite Geanial-GC Corp., Tokyo, Japan) using the direct layering technique. Bonding between the material and dental tissue was achieved using an adhesive agent (G bond-GC Corp., Tokyo, Japan). The prepared specimens, which consisted of a tooth-adhesive-composite system, were immersed in acrylic for easier positioning into the tensile testing machine (Tinius Olsen HlOKS). Contactless optical 3D system ARAMIS 2.0 was used for measuring strain in the veneers. In order to simulate the effect of masticatory forces, the prepared specimens were positioned under a 135 degree angle relative to the applied force. This experimental setup will enable analysis of stress and strain of the tooth-adhesive-veneer system, based on clinically relevant parameters (design of the preparation, material characteristics and angle of the applied force).", publisher = "Society for Structural Integrity and Life – Prof. Dr Stojan Sedmak (DIVK), Belgrade", journal = "22nd European Conference on Fracture - ECF22", title = "Experimental setup for determining strain in dental composite veneers subjected to compressive load", pages = "99-99", url = "https://hdl.handle.net/21.15107/rcub_machinery_6938" }
Milošević, M., Cabunac, J., Milovanović, A., Mitrović, N., Mladenović, G.,& Miletić, V.. (2018). Experimental setup for determining strain in dental composite veneers subjected to compressive load. in 22nd European Conference on Fracture - ECF22 Society for Structural Integrity and Life – Prof. Dr Stojan Sedmak (DIVK), Belgrade., 99-99. https://hdl.handle.net/21.15107/rcub_machinery_6938
Milošević M, Cabunac J, Milovanović A, Mitrović N, Mladenović G, Miletić V. Experimental setup for determining strain in dental composite veneers subjected to compressive load. in 22nd European Conference on Fracture - ECF22. 2018;:99-99. https://hdl.handle.net/21.15107/rcub_machinery_6938 .
Milošević, Miloš, Cabunac, Jovan, Milovanović, Aleksa, Mitrović, Nenad, Mladenović, Goran, Miletić, Vesna, "Experimental setup for determining strain in dental composite veneers subjected to compressive load" in 22nd European Conference on Fracture - ECF22 (2018):99-99, https://hdl.handle.net/21.15107/rcub_machinery_6938 .