Experimental measurement of fouling resistance in the heat exchanger of a geothermal heating system
Само за регистроване кориснике
2006
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
Experimental measurements of fouling resistance were carried out in a double-pipe heat exchanger (HE), with geothermal water flowing in the inner tube and tap water in the annular space. Tests were performed using waters from a geothermal well in central Serbia whose production temperature remained practically constant (52 degrees C) throughout the 90-day experiment. Analysis of the data showed that the change in fouling resistance was a linear function of time.
Кључне речи:
Serbia / heat exchanger / geothermal water / fouling resistanceИзвор:
Geothermics, 2006, 35, 1, 79-86Издавач:
- Pergamon-Elsevier Science Ltd, Oxford
DOI: 10.1016/j.geothermics.2005.11.003
ISSN: 0375-6505
WoS: 000236161100007
Scopus: 2-s2.0-32644446916
Колекције
Институција/група
Mašinski fakultetTY - JOUR AU - Milanović, P AU - Jaćimović, Branislav M. AU - Genić, Srbislav PY - 2006 UR - https://machinery.mas.bg.ac.rs/handle/123456789/647 AB - Experimental measurements of fouling resistance were carried out in a double-pipe heat exchanger (HE), with geothermal water flowing in the inner tube and tap water in the annular space. Tests were performed using waters from a geothermal well in central Serbia whose production temperature remained practically constant (52 degrees C) throughout the 90-day experiment. Analysis of the data showed that the change in fouling resistance was a linear function of time. PB - Pergamon-Elsevier Science Ltd, Oxford T2 - Geothermics T1 - Experimental measurement of fouling resistance in the heat exchanger of a geothermal heating system EP - 86 IS - 1 SP - 79 VL - 35 DO - 10.1016/j.geothermics.2005.11.003 ER -
@article{ author = "Milanović, P and Jaćimović, Branislav M. and Genić, Srbislav", year = "2006", abstract = "Experimental measurements of fouling resistance were carried out in a double-pipe heat exchanger (HE), with geothermal water flowing in the inner tube and tap water in the annular space. Tests were performed using waters from a geothermal well in central Serbia whose production temperature remained practically constant (52 degrees C) throughout the 90-day experiment. Analysis of the data showed that the change in fouling resistance was a linear function of time.", publisher = "Pergamon-Elsevier Science Ltd, Oxford", journal = "Geothermics", title = "Experimental measurement of fouling resistance in the heat exchanger of a geothermal heating system", pages = "86-79", number = "1", volume = "35", doi = "10.1016/j.geothermics.2005.11.003" }
Milanović, P., Jaćimović, B. M.,& Genić, S.. (2006). Experimental measurement of fouling resistance in the heat exchanger of a geothermal heating system. in Geothermics Pergamon-Elsevier Science Ltd, Oxford., 35(1), 79-86. https://doi.org/10.1016/j.geothermics.2005.11.003
Milanović P, Jaćimović BM, Genić S. Experimental measurement of fouling resistance in the heat exchanger of a geothermal heating system. in Geothermics. 2006;35(1):79-86. doi:10.1016/j.geothermics.2005.11.003 .
Milanović, P, Jaćimović, Branislav M., Genić, Srbislav, "Experimental measurement of fouling resistance in the heat exchanger of a geothermal heating system" in Geothermics, 35, no. 1 (2006):79-86, https://doi.org/10.1016/j.geothermics.2005.11.003 . .