dc.description.abstractThis paper presents comparison of results obtained by dynamic pressure transducers, which measure fast pressure changes during transients, installed on experimental setup for investigation of water hammer and its side effects, unsteady friction, cavitation, column separation and fluid structure interaction (FSI). Apparatus, situated at the Faculty of Mechanical Engineering in Podgorica, is comprised of high presusurized tank, steel pipeline and outflow tank. Four dynamic and four absolute high-frequency pressure transducers are positioned within the valve units along the pipeline. Results of the dynamic and absolute pressure measurements are compared and analyzed. Proposals for the future improvement of experimental setup are given.sr
dc.language.isoensr
dc.publisherDruštvo termičara Srbijesr
dc.relationResearch and development of improved measures for protection of hydropower plants during hydraulic transients in order to increase their reliability and energy efficiencysr
dc.rightsclosedAccesssr
dc.sourceVII Regional Conference „Industrial Energy and Environmental Protection in South Eastern European Countries IEEP ‘19sr
dc.subjectwater hammersr
dc.subjectexperimental setupsr
dc.subjectdynamic pressure transducerssr
dc.titleComparison of dynamic pressure transducers on experimental water hammer setupsr
dc.typeconferenceObjectsr
dc.rights.licenseARRsr
dc.citation.rankM33
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_machinery_6409
dc.type.versionpublishedVersionsr


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу