This paper deals with experimental investigations of the influence of electro-pneumatically operated ball valve (EPV) on fluid-structure interaction (FSI) effect. The experimental setup for investigation of water hammer and its side effects, unsteady friction, cavitation, column separation and FSI is installed at Faculty of Mechanical Engineering, Podgorica, Montenegro. Experimental runs have been performed with different initial values of pressure in the upstream end high-pressurized tank and with EPV fixed and released. Some
of the obtained results are presented and conclusions are given.
Кључне речи:
fluid-structure interaction / experimental resultsИзвор:
6th IAHR Europe Congress, 2021Финансирање / пројекти:
- Research and development of improved measures for protection of hydropower plants during hydraulic transients in order to increase their reliability and energy efficiency
Колекције
Институција/група
Mašinski fakultetTY - CONF AU - Brđanin, Radislav AU - Karadžić, Uroš AU - Bergant, Anton AU - Božić, Ivan PY - 2021 UR - https://machinery.mas.bg.ac.rs/handle/123456789/6381 AB - This paper deals with experimental investigations of the influence of electro-pneumatically operated ball valve (EPV) on fluid-structure interaction (FSI) effect. The experimental setup for investigation of water hammer and its side effects, unsteady friction, cavitation, column separation and FSI is installed at Faculty of Mechanical Engineering, Podgorica, Montenegro. Experimental runs have been performed with different initial values of pressure in the upstream end high-pressurized tank and with EPV fixed and released. Some of the obtained results are presented and conclusions are given. C3 - 6th IAHR Europe Congress T1 - FSI Effects Caused by Electro-pneumatically Operated Ball Valve UR - https://hdl.handle.net/21.15107/rcub_machinery_6381 ER -
@conference{ author = "Brđanin, Radislav and Karadžić, Uroš and Bergant, Anton and Božić, Ivan", year = "2021", abstract = "This paper deals with experimental investigations of the influence of electro-pneumatically operated ball valve (EPV) on fluid-structure interaction (FSI) effect. The experimental setup for investigation of water hammer and its side effects, unsteady friction, cavitation, column separation and FSI is installed at Faculty of Mechanical Engineering, Podgorica, Montenegro. Experimental runs have been performed with different initial values of pressure in the upstream end high-pressurized tank and with EPV fixed and released. Some of the obtained results are presented and conclusions are given.", journal = "6th IAHR Europe Congress", title = "FSI Effects Caused by Electro-pneumatically Operated Ball Valve", url = "https://hdl.handle.net/21.15107/rcub_machinery_6381" }
Brđanin, R., Karadžić, U., Bergant, A.,& Božić, I.. (2021). FSI Effects Caused by Electro-pneumatically Operated Ball Valve. in 6th IAHR Europe Congress. https://hdl.handle.net/21.15107/rcub_machinery_6381
Brđanin R, Karadžić U, Bergant A, Božić I. FSI Effects Caused by Electro-pneumatically Operated Ball Valve. in 6th IAHR Europe Congress. 2021;. https://hdl.handle.net/21.15107/rcub_machinery_6381 .
Brđanin, Radislav, Karadžić, Uroš, Bergant, Anton, Božić, Ivan, "FSI Effects Caused by Electro-pneumatically Operated Ball Valve" in 6th IAHR Europe Congress (2021), https://hdl.handle.net/21.15107/rcub_machinery_6381 .