Effect of DIC equipment calibration on deformation measuring errors
Апстракт
Shown in this paper is the application of stereometric deformation measuring method on a welded
joint made of steel P460NL1, along with its drawbacks. Stereometric measuring of deformation is a technique with a wide application in measuring of deformation and displacement in objects with simple or complex geometry. Despite its high accuracy, it is susceptible to errors which could provide an inaccurate insight into the behavior of the tested object, thereby resulting in incorrect material properties. This typically occurs due to the inaccurate calibration of the ARAMIS measuring system. In case of welded joint, the effects of heat and chemical composition of various parts of the welded joint are also present, which makes the problem more complex, and the conclusions may be incorrect or insufficiently accurate.
Кључне речи:
Stereometric optical systems / calibration / ARAMIS software / welded joint / deformationИзвор:
2015, 48-53Финансирање / пројекти:
- Развој савремених метода дијагностике и испитивања машинских структура (RS-MESTD-Technological Development (TD or TR)-35040)
Колекције
Институција/група
Inovacioni centarTY - CONF AU - Đorđević, Branislav AU - Tatić, Uroš AU - Vučetić, Filip AU - Milošević, Miloš AU - Sedmak, Simon PY - 2015 UR - https://machinery.mas.bg.ac.rs/handle/123456789/6117 AB - Shown in this paper is the application of stereometric deformation measuring method on a welded joint made of steel P460NL1, along with its drawbacks. Stereometric measuring of deformation is a technique with a wide application in measuring of deformation and displacement in objects with simple or complex geometry. Despite its high accuracy, it is susceptible to errors which could provide an inaccurate insight into the behavior of the tested object, thereby resulting in incorrect material properties. This typically occurs due to the inaccurate calibration of the ARAMIS measuring system. In case of welded joint, the effects of heat and chemical composition of various parts of the welded joint are also present, which makes the problem more complex, and the conclusions may be incorrect or insufficiently accurate. T1 - Effect of DIC equipment calibration on deformation measuring errors EP - 53 SP - 48 UR - https://hdl.handle.net/21.15107/rcub_machinery_6117 ER -
@conference{ author = "Đorđević, Branislav and Tatić, Uroš and Vučetić, Filip and Milošević, Miloš and Sedmak, Simon", year = "2015", abstract = "Shown in this paper is the application of stereometric deformation measuring method on a welded joint made of steel P460NL1, along with its drawbacks. Stereometric measuring of deformation is a technique with a wide application in measuring of deformation and displacement in objects with simple or complex geometry. Despite its high accuracy, it is susceptible to errors which could provide an inaccurate insight into the behavior of the tested object, thereby resulting in incorrect material properties. This typically occurs due to the inaccurate calibration of the ARAMIS measuring system. In case of welded joint, the effects of heat and chemical composition of various parts of the welded joint are also present, which makes the problem more complex, and the conclusions may be incorrect or insufficiently accurate.", title = "Effect of DIC equipment calibration on deformation measuring errors", pages = "53-48", url = "https://hdl.handle.net/21.15107/rcub_machinery_6117" }
Đorđević, B., Tatić, U., Vučetić, F., Milošević, M.,& Sedmak, S.. (2015). Effect of DIC equipment calibration on deformation measuring errors. , 48-53. https://hdl.handle.net/21.15107/rcub_machinery_6117
Đorđević B, Tatić U, Vučetić F, Milošević M, Sedmak S. Effect of DIC equipment calibration on deformation measuring errors. 2015;:48-53. https://hdl.handle.net/21.15107/rcub_machinery_6117 .
Đorđević, Branislav, Tatić, Uroš, Vučetić, Filip, Milošević, Miloš, Sedmak, Simon, "Effect of DIC equipment calibration on deformation measuring errors" (2015):48-53, https://hdl.handle.net/21.15107/rcub_machinery_6117 .