Research on the air pressure drop in plate finned tube heat exchangers
Само за регистроване кориснике
2006
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
In order to establish a reliable procedure for estimation of air pressure drop, experiments on plate finned tube heat exchangers have been conducted, as well as the research on the open literature. The procedure of Kays and London was tested against the experimental data and significant level of uncertainty was found. Using own experimental data, as well as previously published data of Kays and London, new correlation for estimation of air pressure drop has been established. Statistical parameters of new correlation enable the conclusion that it can be used for wide range of Reynolds numbers.
Кључне речи:
pressure / measure / heat exchangeur / finned tube / experiment / correlation / air flowИзвор:
International Journal of Refrigeration-Revue Internationale Du Froid, 2006, 29, 7, 1138-1143Издавач:
- Elsevier Sci Ltd, Oxford
DOI: 10.1016/j.ijrefrig.2006.02.003
ISSN: 0140-7007
WoS: 000240885300010
Scopus: 2-s2.0-33748047510
Колекције
Институција/група
Mašinski fakultetTY - JOUR AU - Jaćimović, Branislav M. AU - Genić, Srbislav AU - Latinović, Boris R. PY - 2006 UR - https://machinery.mas.bg.ac.rs/handle/123456789/577 AB - In order to establish a reliable procedure for estimation of air pressure drop, experiments on plate finned tube heat exchangers have been conducted, as well as the research on the open literature. The procedure of Kays and London was tested against the experimental data and significant level of uncertainty was found. Using own experimental data, as well as previously published data of Kays and London, new correlation for estimation of air pressure drop has been established. Statistical parameters of new correlation enable the conclusion that it can be used for wide range of Reynolds numbers. PB - Elsevier Sci Ltd, Oxford T2 - International Journal of Refrigeration-Revue Internationale Du Froid T1 - Research on the air pressure drop in plate finned tube heat exchangers EP - 1143 IS - 7 SP - 1138 VL - 29 DO - 10.1016/j.ijrefrig.2006.02.003 ER -
@article{ author = "Jaćimović, Branislav M. and Genić, Srbislav and Latinović, Boris R.", year = "2006", abstract = "In order to establish a reliable procedure for estimation of air pressure drop, experiments on plate finned tube heat exchangers have been conducted, as well as the research on the open literature. The procedure of Kays and London was tested against the experimental data and significant level of uncertainty was found. Using own experimental data, as well as previously published data of Kays and London, new correlation for estimation of air pressure drop has been established. Statistical parameters of new correlation enable the conclusion that it can be used for wide range of Reynolds numbers.", publisher = "Elsevier Sci Ltd, Oxford", journal = "International Journal of Refrigeration-Revue Internationale Du Froid", title = "Research on the air pressure drop in plate finned tube heat exchangers", pages = "1143-1138", number = "7", volume = "29", doi = "10.1016/j.ijrefrig.2006.02.003" }
Jaćimović, B. M., Genić, S.,& Latinović, B. R.. (2006). Research on the air pressure drop in plate finned tube heat exchangers. in International Journal of Refrigeration-Revue Internationale Du Froid Elsevier Sci Ltd, Oxford., 29(7), 1138-1143. https://doi.org/10.1016/j.ijrefrig.2006.02.003
Jaćimović BM, Genić S, Latinović BR. Research on the air pressure drop in plate finned tube heat exchangers. in International Journal of Refrigeration-Revue Internationale Du Froid. 2006;29(7):1138-1143. doi:10.1016/j.ijrefrig.2006.02.003 .
Jaćimović, Branislav M., Genić, Srbislav, Latinović, Boris R., "Research on the air pressure drop in plate finned tube heat exchangers" in International Journal of Refrigeration-Revue Internationale Du Froid, 29, no. 7 (2006):1138-1143, https://doi.org/10.1016/j.ijrefrig.2006.02.003 . .