Experimental Testing of Wastewater Treatment Efficiency in the Facilities Mitrovićev Dom and Čarapićev Brest
Abstract
SBR (sequencing batch reactor) plants for wastewater treatment in the "Mitrovićev dom" and "Čarapićev brest" on Avala, are based on the principles of deep aeration using activated sludge as an economical and efficient method of purification municipal wastewater. Samples of the sludge and the municipal wastewater were collected at the inlet and outlet of the plant and the physio-chemical and biological analysis was performed. It is concluded that the biological method of activated sludge reduced the concentration of total suspended matter, BOD5 and COD values to the legally prescribed levels. The concentrations of phosphorus and nitrogen in the effluent were reduced, but the recorded values were not sufficient for the discharge into natural recipients.
Keywords:
Wastewater, Suspended matter, Phosphorus, NitrogenSource:
1st International Conference Ecological Improvement of Devastated Sites for Sustainable Development ECOIDS 2014, 2014, 207-2013Publisher:
- ECOIDS 2014 and Faculty of Applied Ecology Futura, Belgrade
Collections
Institution/Community
Inovacioni centarTY - CONF AU - Kovačević, Sanja AU - Antonijević, Dragi AU - Petrović, Darko PY - 2014 UR - https://machinery.mas.bg.ac.rs/handle/123456789/5664 AB - SBR (sequencing batch reactor) plants for wastewater treatment in the "Mitrovićev dom" and "Čarapićev brest" on Avala, are based on the principles of deep aeration using activated sludge as an economical and efficient method of purification municipal wastewater. Samples of the sludge and the municipal wastewater were collected at the inlet and outlet of the plant and the physio-chemical and biological analysis was performed. It is concluded that the biological method of activated sludge reduced the concentration of total suspended matter, BOD5 and COD values to the legally prescribed levels. The concentrations of phosphorus and nitrogen in the effluent were reduced, but the recorded values were not sufficient for the discharge into natural recipients. PB - ECOIDS 2014 and Faculty of Applied Ecology Futura, Belgrade C3 - 1st International Conference Ecological Improvement of Devastated Sites for Sustainable Development ECOIDS 2014 T1 - Experimental Testing of Wastewater Treatment Efficiency in the Facilities Mitrovićev Dom and Čarapićev Brest EP - 2013 SP - 207 UR - https://hdl.handle.net/21.15107/rcub_machinery_5664 ER -
@conference{ author = "Kovačević, Sanja and Antonijević, Dragi and Petrović, Darko", year = "2014", abstract = "SBR (sequencing batch reactor) plants for wastewater treatment in the "Mitrovićev dom" and "Čarapićev brest" on Avala, are based on the principles of deep aeration using activated sludge as an economical and efficient method of purification municipal wastewater. Samples of the sludge and the municipal wastewater were collected at the inlet and outlet of the plant and the physio-chemical and biological analysis was performed. It is concluded that the biological method of activated sludge reduced the concentration of total suspended matter, BOD5 and COD values to the legally prescribed levels. The concentrations of phosphorus and nitrogen in the effluent were reduced, but the recorded values were not sufficient for the discharge into natural recipients.", publisher = "ECOIDS 2014 and Faculty of Applied Ecology Futura, Belgrade", journal = "1st International Conference Ecological Improvement of Devastated Sites for Sustainable Development ECOIDS 2014", title = "Experimental Testing of Wastewater Treatment Efficiency in the Facilities Mitrovićev Dom and Čarapićev Brest", pages = "2013-207", url = "https://hdl.handle.net/21.15107/rcub_machinery_5664" }
Kovačević, S., Antonijević, D.,& Petrović, D.. (2014). Experimental Testing of Wastewater Treatment Efficiency in the Facilities Mitrovićev Dom and Čarapićev Brest. in 1st International Conference Ecological Improvement of Devastated Sites for Sustainable Development ECOIDS 2014 ECOIDS 2014 and Faculty of Applied Ecology Futura, Belgrade., 207-2013. https://hdl.handle.net/21.15107/rcub_machinery_5664
Kovačević S, Antonijević D, Petrović D. Experimental Testing of Wastewater Treatment Efficiency in the Facilities Mitrovićev Dom and Čarapićev Brest. in 1st International Conference Ecological Improvement of Devastated Sites for Sustainable Development ECOIDS 2014. 2014;:207-2013. https://hdl.handle.net/21.15107/rcub_machinery_5664 .
Kovačević, Sanja, Antonijević, Dragi, Petrović, Darko, "Experimental Testing of Wastewater Treatment Efficiency in the Facilities Mitrovićev Dom and Čarapićev Brest" in 1st International Conference Ecological Improvement of Devastated Sites for Sustainable Development ECOIDS 2014 (2014):207-2013, https://hdl.handle.net/21.15107/rcub_machinery_5664 .