PERFORMANCES INVESTIGATION OF FINNED TUBE AIR COOLER
Conference object (Published version)
Metadata
Show full item recordAbstract
The paper deals with the problems of measurement of respective operating parameters of air cooler with finned tubes. It is given a PI diagram of the tested refrigeration system. The most important geometrical characteristics of this heat exchanger are shown. Experimental work included measurement of thermal performance on a physical model – the heat exchanger, which cooled the air by using secondary refrigerant, which has not changed phase flowing through the pipes. Flow rates and temperatures of working fluids were varied in defined operating ranges of experimental installation, which were sufficient to make generalization of experimentally obtained data. In conclusion, it is given the most important results that were obtained during the experimental and mathematical analysis of this exchanger in terms of cooling and drying air.
Keywords:
heat exchangers / air-cooling coils / staggered tubes / plate fins / experimental setup and mesurements / moisture condensationSource:
Zbornik 47. Međunarodnog kongresa o KGH, 2016Publisher:
- Beograd: SMEITS
Funding / projects:
- Intelligent Control Systems of the Air-conditioning for the Purpose of Achieving Energy Efficient Exploitation Regimes in the Complex Operating Conditions (RS-MESTD-Technological Development (TD or TR)-33047)
- Research and development of equipment and systems for industrial production, storage and processing vegetables and fruits (RS-MESTD-Technological Development (TD or TR)-35043)
Collections
Institution/Community
Mašinski fakultetTY - CONF AU - Milovančević, Uroš AU - Genić, Srbislav AU - Otović, Milena AU - Stevanović, Snežana M. PY - 2016 UR - https://machinery.mas.bg.ac.rs/handle/123456789/5538 AB - The paper deals with the problems of measurement of respective operating parameters of air cooler with finned tubes. It is given a PI diagram of the tested refrigeration system. The most important geometrical characteristics of this heat exchanger are shown. Experimental work included measurement of thermal performance on a physical model – the heat exchanger, which cooled the air by using secondary refrigerant, which has not changed phase flowing through the pipes. Flow rates and temperatures of working fluids were varied in defined operating ranges of experimental installation, which were sufficient to make generalization of experimentally obtained data. In conclusion, it is given the most important results that were obtained during the experimental and mathematical analysis of this exchanger in terms of cooling and drying air. PB - Beograd: SMEITS C3 - Zbornik 47. Međunarodnog kongresa o KGH T1 - PERFORMANCES INVESTIGATION OF FINNED TUBE AIR COOLER UR - https://hdl.handle.net/21.15107/rcub_machinery_5538 ER -
@conference{ author = "Milovančević, Uroš and Genić, Srbislav and Otović, Milena and Stevanović, Snežana M.", year = "2016", abstract = "The paper deals with the problems of measurement of respective operating parameters of air cooler with finned tubes. It is given a PI diagram of the tested refrigeration system. The most important geometrical characteristics of this heat exchanger are shown. Experimental work included measurement of thermal performance on a physical model – the heat exchanger, which cooled the air by using secondary refrigerant, which has not changed phase flowing through the pipes. Flow rates and temperatures of working fluids were varied in defined operating ranges of experimental installation, which were sufficient to make generalization of experimentally obtained data. In conclusion, it is given the most important results that were obtained during the experimental and mathematical analysis of this exchanger in terms of cooling and drying air.", publisher = "Beograd: SMEITS", journal = "Zbornik 47. Međunarodnog kongresa o KGH", title = "PERFORMANCES INVESTIGATION OF FINNED TUBE AIR COOLER", url = "https://hdl.handle.net/21.15107/rcub_machinery_5538" }
Milovančević, U., Genić, S., Otović, M.,& Stevanović, S. M.. (2016). PERFORMANCES INVESTIGATION OF FINNED TUBE AIR COOLER. in Zbornik 47. Međunarodnog kongresa o KGH Beograd: SMEITS.. https://hdl.handle.net/21.15107/rcub_machinery_5538
Milovančević U, Genić S, Otović M, Stevanović SM. PERFORMANCES INVESTIGATION OF FINNED TUBE AIR COOLER. in Zbornik 47. Međunarodnog kongresa o KGH. 2016;. https://hdl.handle.net/21.15107/rcub_machinery_5538 .
Milovančević, Uroš, Genić, Srbislav, Otović, Milena, Stevanović, Snežana M., "PERFORMANCES INVESTIGATION OF FINNED TUBE AIR COOLER" in Zbornik 47. Međunarodnog kongresa o KGH (2016), https://hdl.handle.net/21.15107/rcub_machinery_5538 .