Prikaz osnovnih podataka o dokumentu
Efficiency analisys of the heat pump system for raw milk cooling with precooler and possibility for waste heat recovery through sanitary water heating
dc.creator | Zlatanović, Ivan | |
dc.creator | Radojičić, Dušan | |
dc.creator | Radivojević, Dušan | |
dc.creator | Pajić, Miloš | |
dc.date.accessioned | 2023-03-06T12:27:52Z | |
dc.date.available | 2023-03-06T12:27:52Z | |
dc.date.issued | 2014 | |
dc.identifier.issn | 1821-4487 | |
dc.identifier.uri | https://machinery.mas.bg.ac.rs/handle/123456789/5333 | |
dc.description.abstract | Contemporary livestock production implies production of highly valuable, biologically and chemically safe products. Dairy pro duction has no exception too. On the contrary, the quality standards for raw milk are highly increased. The quality of raw milk is de fined by its chemical composition and the total count of microorganisms in control volume. In this paper we discussed the perform ance of advanced system for heat recovery from raw milk and its application in the process of preheating and preparation of process water. The energy and exergy efficiency of one of such systems were analyzed. It was determined that the implementation of the sys tem for milk cooling with precooling and using the waste heat for preheating process water could achieve significant savings. The system consists of "milk to water" heat pump, pre-cooler for milk cooling and storage tank for process water with heating possibility. Values of exergy efficiency of each component of system and potential improving of components performances were determined. Also, the exergy efficiency and potential improvement of complete system were determined | sr |
dc.language.iso | en | sr |
dc.publisher | Nacionalno društvo za procesnu tehniku i energetiku u poljoprivredi (bivše društvo YUPTEP) | sr |
dc.relation | info:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/31051/RS// | sr |
dc.rights | openAccess | sr |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.source | Journal on Processing and energy in agriculture (PTEP) | sr |
dc.subject | Energy efficiency | sr |
dc.subject | heat pump | sr |
dc.subject | milk | sr |
dc.subject | cooling | sr |
dc.subject | exergy | sr |
dc.title | Efficiency analisys of the heat pump system for raw milk cooling with precooler and possibility for waste heat recovery through sanitary water heating | sr |
dc.type | article | sr |
dc.rights.license | BY | sr |
dc.citation.epage | 203 | |
dc.citation.issue | 5 | |
dc.citation.spage | 200 | |
dc.citation.volume | 18 | |
dc.identifier.fulltext | http://machinery.mas.bg.ac.rs/bitstream/id/13005/bitstream_13005.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_machinery_5333 | |
dc.type.version | publishedVersion | sr |