dc.description.abstractFor a data centre in Belgrade, a comparison was made regarding initial investment and operation costs between a trigeneration system (combined heat and power production) and a conventional air‑conditioning system. According to the current ratio of natural gas prices and electricity prices, trigeneration is not profitable for consumers in Serbia. However, according to the ratio of energy prices in European countries, economic feasibility of trigeneration as well as its high energy efficiency is the reason to expect a major market break of trigeneration systems.sr
dc.description.abstractZa jedan računski centar u Beogradu izvršeno je poređenje investicionih i eksploatacionih troškova za konvencionalni sistem klimatizacije takvih objekata i postrojenja za trigeneraciju (kombinovana proizvodnja električne energije i toplote za grejanje i hlađenje). Prema trenutnom odnosu cena osnovnih energenata u ovim sistemima (električne energije i prirodnog gasa), sistemi trigeneracije nisu isplativi korisnicima u Srbiji. Međutim, prema cenama energenata u okruženju, trigeneracija je ne samo energetski, nego i ekonomski isplativa i očekuje se njen veći prodor na tržište.sr
dc.language.isosrsr
dc.publisherBeograd : SMEITSsr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceProceedings of the 40th International HVAC&R Congres, Belgradesr
dc.subjecttrigenerationsr
dc.subjectdata centresr
dc.subjectgas enginesr
dc.subjectabsorption refrigeration systemsr
dc.subjecteconomic analysissr
dc.titlePrimena sistema trigeneracije i analiza prednosti u odnosu na konvencionalni sistem klimatizacije računskog centrasr
dc.titleTrigeneration and advantage analysis in compare to conventional air-conditioning of data centersr
dc.typeconferenceObjectsr
dc.rights.licenseBY-NC-NDsr
dc.citation.epage455
dc.citation.issue1
dc.citation.rankM33
dc.citation.spage445
dc.citation.volume40
dc.identifier.fulltexthttp://machinery.mas.bg.ac.rs/bitstream/id/11326/5869-25-17860-1-10-20191107.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_machinery_5056
dc.type.versionpublishedVersionsr


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу