High Accuracy Installation for Flow Meter Calibration with Weighing Method
Нема приказа
Аутори
Ilić, DejanJanković, Novica
Slijepčević, Miloš
Čantrak, Đorđe
Остала ауторства
Latinović, TihomirКонференцијски прилог (Нерецензирана верзија)
Метаподаци
Приказ свих података о документуАпстракт
One of the most important characteristics of the fluid flow meter is its accuracy. In order to determine the highest possible accuracy of the flow meter, it is necessary to calibrate the flow meter on an adequate installation. It is necessary that installation for precise flow meter calibrations meets demands of the relevant standards: quality installation, appropriate calibration methodology, instruments of high accuracy and satisfactory measurement uncertainty. Designed and manufactured installation for flow meters calibration (measurement of liquid flow in closed conduits) up to 10 l/min, based on weighing method, is presented in this paper. Modified measurement methodology, which mainly follows standard ISO 4185, is presented in this paper. The created 3D model of the whole installation is presented and afterwards used for numerical experiments. Two numerical meshes were tested. First approach had a half a million cells and the second mesh was consisted of approximately 1.6 million... cells. Both meshes were unstructured. Numerical results were used for installation test before manufacturing and production. The test rig was manufactured after the numerical results evaluation. Flow measurement experimental results and measurement uncertainty for three operating regimes are analyzed and reported. It was shown, both experimentally and numerically, that uniform flow is achieved in the straight measurement section. This is of great importance for flow measurement calibration.
Извор:
Sixth International Conference on Applied Sciences ICAS2018, Book of Abstracts, pp. 121, 2018Издавач:
- UNIVERSITY OF BANJA LUKA FACULTY OF MECHANICAL ENGINEERING
- UNIVERSITY OF TIMISOARA FACULTY OF ENGINEERING HUNEDOARA
URI
https://icas.science/forms/Program_ICAS2018.pdfhttps://machinery.mas.bg.ac.rs/handle/123456789/4985
Колекције
Институција/група
Mašinski fakultetTY - CONF AU - Ilić, Dejan AU - Janković, Novica AU - Slijepčević, Miloš AU - Čantrak, Đorđe PY - 2018 UR - https://icas.science/forms/Program_ICAS2018.pdf UR - https://machinery.mas.bg.ac.rs/handle/123456789/4985 AB - One of the most important characteristics of the fluid flow meter is its accuracy. In order to determine the highest possible accuracy of the flow meter, it is necessary to calibrate the flow meter on an adequate installation. It is necessary that installation for precise flow meter calibrations meets demands of the relevant standards: quality installation, appropriate calibration methodology, instruments of high accuracy and satisfactory measurement uncertainty. Designed and manufactured installation for flow meters calibration (measurement of liquid flow in closed conduits) up to 10 l/min, based on weighing method, is presented in this paper. Modified measurement methodology, which mainly follows standard ISO 4185, is presented in this paper. The created 3D model of the whole installation is presented and afterwards used for numerical experiments. Two numerical meshes were tested. First approach had a half a million cells and the second mesh was consisted of approximately 1.6 million cells. Both meshes were unstructured. Numerical results were used for installation test before manufacturing and production. The test rig was manufactured after the numerical results evaluation. Flow measurement experimental results and measurement uncertainty for three operating regimes are analyzed and reported. It was shown, both experimentally and numerically, that uniform flow is achieved in the straight measurement section. This is of great importance for flow measurement calibration. PB - UNIVERSITY OF BANJA LUKA FACULTY OF MECHANICAL ENGINEERING PB - UNIVERSITY OF TIMISOARA FACULTY OF ENGINEERING HUNEDOARA C3 - Sixth International Conference on Applied Sciences ICAS2018, Book of Abstracts, pp. 121 T1 - High Accuracy Installation for Flow Meter Calibration with Weighing Method UR - https://hdl.handle.net/21.15107/rcub_machinery_4985 ER -
@conference{ author = "Ilić, Dejan and Janković, Novica and Slijepčević, Miloš and Čantrak, Đorđe", year = "2018", abstract = "One of the most important characteristics of the fluid flow meter is its accuracy. In order to determine the highest possible accuracy of the flow meter, it is necessary to calibrate the flow meter on an adequate installation. It is necessary that installation for precise flow meter calibrations meets demands of the relevant standards: quality installation, appropriate calibration methodology, instruments of high accuracy and satisfactory measurement uncertainty. Designed and manufactured installation for flow meters calibration (measurement of liquid flow in closed conduits) up to 10 l/min, based on weighing method, is presented in this paper. Modified measurement methodology, which mainly follows standard ISO 4185, is presented in this paper. The created 3D model of the whole installation is presented and afterwards used for numerical experiments. Two numerical meshes were tested. First approach had a half a million cells and the second mesh was consisted of approximately 1.6 million cells. Both meshes were unstructured. Numerical results were used for installation test before manufacturing and production. The test rig was manufactured after the numerical results evaluation. Flow measurement experimental results and measurement uncertainty for three operating regimes are analyzed and reported. It was shown, both experimentally and numerically, that uniform flow is achieved in the straight measurement section. This is of great importance for flow measurement calibration.", publisher = "UNIVERSITY OF BANJA LUKA FACULTY OF MECHANICAL ENGINEERING, UNIVERSITY OF TIMISOARA FACULTY OF ENGINEERING HUNEDOARA", journal = "Sixth International Conference on Applied Sciences ICAS2018, Book of Abstracts, pp. 121", title = "High Accuracy Installation for Flow Meter Calibration with Weighing Method", url = "https://hdl.handle.net/21.15107/rcub_machinery_4985" }
Ilić, D., Janković, N., Slijepčević, M.,& Čantrak, Đ.. (2018). High Accuracy Installation for Flow Meter Calibration with Weighing Method. in Sixth International Conference on Applied Sciences ICAS2018, Book of Abstracts, pp. 121 UNIVERSITY OF BANJA LUKA FACULTY OF MECHANICAL ENGINEERING.. https://hdl.handle.net/21.15107/rcub_machinery_4985
Ilić D, Janković N, Slijepčević M, Čantrak Đ. High Accuracy Installation for Flow Meter Calibration with Weighing Method. in Sixth International Conference on Applied Sciences ICAS2018, Book of Abstracts, pp. 121. 2018;. https://hdl.handle.net/21.15107/rcub_machinery_4985 .
Ilić, Dejan, Janković, Novica, Slijepčević, Miloš, Čantrak, Đorđe, "High Accuracy Installation for Flow Meter Calibration with Weighing Method" in Sixth International Conference on Applied Sciences ICAS2018, Book of Abstracts, pp. 121 (2018), https://hdl.handle.net/21.15107/rcub_machinery_4985 .