Service problems of fresh air fan of fossil fuel power plant - Part II construction design improvement
dc.creator | Mitrović, Radivoje | |
dc.creator | Ristivojević, Mileta | |
dc.creator | Stefanović, N. | |
dc.creator | Stamenić, Zoran | |
dc.creator | Lazović, Tatjana | |
dc.date.accessioned | 2022-09-19T15:46:03Z | |
dc.date.available | 2022-09-19T15:46:03Z | |
dc.date.issued | 2005 | |
dc.identifier.uri | https://machinery.mas.bg.ac.rs/handle/123456789/471 | |
dc.description.abstract | According to improper bearing mounting on the a fresh air fan shaft in fosilfuel power plant, loss of operational reliability of immobile spherical roller bearing took place. That caused total failure of the fresh air fan installation. The consequence of this failure was a damage of the impeller with blades, and a total fracture of the shaft at the bearing sleeve spot. A comprehensive investigation took place to determine a cause of installation failure. In repair, as a constructional improvement, the bearing seating design was changed with purpose of bearing life extension, due to protection of asset fresh air fan components from destruction. | en |
dc.rights | restrictedAccess | |
dc.source | 11th International Conference on Fracture 2005, ICF11 | |
dc.title | Service problems of fresh air fan of fossil fuel power plant - Part II construction design improvement | en |
dc.type | conferenceObject | |
dc.rights.license | ARR | |
dc.citation.epage | 2327 | |
dc.citation.other | 3: 2322-2327 | |
dc.citation.spage | 2322 | |
dc.citation.volume | 3 | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_machinery_471 | |
dc.identifier.scopus | 2-s2.0-84869793451 | |