Indoor Air Quality in Office Buildings – experimental investigation
Апстракт
This paper presents the part of the research that has been done at the Universities both in
Belgrade, Serbia and Thessaloniki, Greece, taking into account indoor air quality (IAQ) in office
buildings and classrooms. The measurements that are presented were done in Process Equipment Design Laboratory at Aristotle University Thessaloniki, during March 2015. IEQ, regarding air temperature, relative humidity and CO2 concentration in two representative offices is observed. The similar offices are located one on the north-east and the other one on the south-west side of the University building, so as to be representative of the orientation’s impact. Furthermore, the impact of natural ventilation on CO2 concentration and temperature is monitored, together with the offices’ occupancy. Recommended parameters for IAQ are compared and discussed on the base of several standards: SRPS EN 15251:2010, ASHRAE standards 55 and 62.1 and ISO 7730. The main objectives, as set from these standards are di...scussed, together with the investigation results.
Кључне речи:
ASHRAE standards 55 and 62.1 / Building occupancy / CO2 concentration and temperature measurements / IAQ / SRPS EN 15251:2010Извор:
Proceedings of 17th Symposium on Thermal Science and Engineering of Serbia, Sokobanja, Serbia, October 20–23, 2015, 2015Издавач:
- University of Niš, Faculty of Mechanical Engineering
Финансирање / пројекти:
- Интелигентни системи управљања климатизације у циљу постизања енергетски ефикасних режима у сложеним условима експлоатације (RS-MESTD-Technological Development (TD or TR)-33047)
Колекције
Институција/група
Mašinski fakultetTY - CONF AU - Bajc, Tamara AU - Todorović, Maja AU - Papadopoulos, Agis PY - 2015 UR - https://machinery.mas.bg.ac.rs/handle/123456789/4444 AB - This paper presents the part of the research that has been done at the Universities both in Belgrade, Serbia and Thessaloniki, Greece, taking into account indoor air quality (IAQ) in office buildings and classrooms. The measurements that are presented were done in Process Equipment Design Laboratory at Aristotle University Thessaloniki, during March 2015. IEQ, regarding air temperature, relative humidity and CO2 concentration in two representative offices is observed. The similar offices are located one on the north-east and the other one on the south-west side of the University building, so as to be representative of the orientation’s impact. Furthermore, the impact of natural ventilation on CO2 concentration and temperature is monitored, together with the offices’ occupancy. Recommended parameters for IAQ are compared and discussed on the base of several standards: SRPS EN 15251:2010, ASHRAE standards 55 and 62.1 and ISO 7730. The main objectives, as set from these standards are discussed, together with the investigation results. PB - University of Niš, Faculty of Mechanical Engineering C3 - Proceedings of 17th Symposium on Thermal Science and Engineering of Serbia, Sokobanja, Serbia, October 20–23, 2015 T1 - Indoor Air Quality in Office Buildings – experimental investigation UR - https://hdl.handle.net/21.15107/rcub_machinery_4444 ER -
@conference{ author = "Bajc, Tamara and Todorović, Maja and Papadopoulos, Agis", year = "2015", abstract = "This paper presents the part of the research that has been done at the Universities both in Belgrade, Serbia and Thessaloniki, Greece, taking into account indoor air quality (IAQ) in office buildings and classrooms. The measurements that are presented were done in Process Equipment Design Laboratory at Aristotle University Thessaloniki, during March 2015. IEQ, regarding air temperature, relative humidity and CO2 concentration in two representative offices is observed. The similar offices are located one on the north-east and the other one on the south-west side of the University building, so as to be representative of the orientation’s impact. Furthermore, the impact of natural ventilation on CO2 concentration and temperature is monitored, together with the offices’ occupancy. Recommended parameters for IAQ are compared and discussed on the base of several standards: SRPS EN 15251:2010, ASHRAE standards 55 and 62.1 and ISO 7730. The main objectives, as set from these standards are discussed, together with the investigation results.", publisher = "University of Niš, Faculty of Mechanical Engineering", journal = "Proceedings of 17th Symposium on Thermal Science and Engineering of Serbia, Sokobanja, Serbia, October 20–23, 2015", title = "Indoor Air Quality in Office Buildings – experimental investigation", url = "https://hdl.handle.net/21.15107/rcub_machinery_4444" }
Bajc, T., Todorović, M.,& Papadopoulos, A.. (2015). Indoor Air Quality in Office Buildings – experimental investigation. in Proceedings of 17th Symposium on Thermal Science and Engineering of Serbia, Sokobanja, Serbia, October 20–23, 2015 University of Niš, Faculty of Mechanical Engineering.. https://hdl.handle.net/21.15107/rcub_machinery_4444
Bajc T, Todorović M, Papadopoulos A. Indoor Air Quality in Office Buildings – experimental investigation. in Proceedings of 17th Symposium on Thermal Science and Engineering of Serbia, Sokobanja, Serbia, October 20–23, 2015. 2015;. https://hdl.handle.net/21.15107/rcub_machinery_4444 .
Bajc, Tamara, Todorović, Maja, Papadopoulos, Agis, "Indoor Air Quality in Office Buildings – experimental investigation" in Proceedings of 17th Symposium on Thermal Science and Engineering of Serbia, Sokobanja, Serbia, October 20–23, 2015 (2015), https://hdl.handle.net/21.15107/rcub_machinery_4444 .