Претраживање
Приказ резултата 1-2 од 2
Integrity assessment of ammonia spherical storage tank
(Elsevier Science Bv, Amsterdam, 2018)
The integrity of the ammonia spherical tank (with a volume of 1800 m3 and the outer diameter of 15120 mm, nominal wall thickness 30 mm) was analyzed due to discovered cracks on the longitudinal and transverse but joints ...
Application of Fracture Mechanics Parameters to Spherical Storage Tank Integrity Assessment
(Univ Osijek, Tech Fac, Slavonski Brod, 2020)
Fracture mechanics parameters have been applied to assess pressure vessel integrity. The pressure vessel analysed here was the ammonia spherical tank (volume of 1800 m(3), outer diameter 15.12 m, thickness 30 mm) where ...