Search
Now showing items 1-2 of 2
Laboratory Tests of a Hybrid Metal-Composite Transport Helicopter Blade Segment
(Springer, New York, 2012)
Experimental acquisition and verification of structural properties of an actual helicopter main rotor blade segment have been done with an aim to validate the capability of bonded joints of these structural elements to ...
Digital Image Correlation Analysis of Vertically Loaded Cylindrical Ti-Implants With Straight and Angled Abutments
(Springer, New York, 2016)
The purpose of this study was to investigate the influence of the abutment angulation upon the strain distribution pattern for the vertical loading situation by means of the digital image correlation (DIC) method. In ...