Претраживање
Приказ резултата 1-2 од 2
Primary control reserve of electric power by feedwater flow rate change through an additional economizer - A case study of the thermal power plant "Nikola Tesla B"
(Pergamon-Elsevier Science Ltd, Oxford, 2018)
Coal-fired thermal power plants (TPPs) had been generally designed to cover base loads of electricity consumption. Nowadays, they should be flexible to participate in the primary frequency control of electric system, ...
Efficiency and power upgrade at the aged lignite-fired power plant by flue gas waste heat utilization: High pressure versus low pressure economizer installation
(Pergamon-Elsevier Science Ltd, Oxford, 2019)
A substantial potential exists for the recovery of flue gas waste heat at aged coal-fired power plants. High and low pressure economizers (HPE, LPE) can be applied for this purpose. Two cases of the feedwater supply to the ...