The influence of the GM tube insulation parameters on the GM counter characteristics
Samo za registrovane korisnike
2022
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
The paper presents the results of testing the Geiger-Muller chamber cathode radii on the GM counters characteristics. The influence of the cathode radius is tested on: 1 - the GM counter characteristic; 2 - the length and plateau slope; and 3 - the GM counter chamber lifetime. The influence of small amounts of electronegative gas in the GM chamber working gas on the observed characteristics was also analyzed. The obtained results differ drastically from the results of similar tests presented in previously published papers on similar topics. This result is explained by the fact that the law of similarity for gas emissions was taken into consideration when making the tested tubes (i.e., the mean free path length of the electron was treated as a geometric parameter). In that way, the relevant results for the application of GM counters in practice were obtained. The result obtained with a small percentage of electronegative gas in the three-component mixture of gases noble gas + quenching ...gas + electronegative gas confirms the positive synergistic effect of the electronegative gas addition. This result contradicts the general view that GM chamber working gas must not contain electronegative gas.
Ključne reči:
Working gas composition / GM counter / GM chamber RadiusIzvor:
Vacuum, 2022, 196Izdavač:
- Pergamon-Elsevier Science Ltd, Oxford
DOI: 10.1016/j.vacuum.2021.110755
ISSN: 0042-207X
WoS: 000732988200006
Scopus: 2-s2.0-85120696697
Kolekcije
Institucija/grupa
Mašinski fakultetTY - JOUR AU - Arbutina, Dalibor AU - Vasić-Milovanović, Aleksandra AU - Nedić, Teodora M. PY - 2022 UR - https://machinery.mas.bg.ac.rs/handle/123456789/3734 AB - The paper presents the results of testing the Geiger-Muller chamber cathode radii on the GM counters characteristics. The influence of the cathode radius is tested on: 1 - the GM counter characteristic; 2 - the length and plateau slope; and 3 - the GM counter chamber lifetime. The influence of small amounts of electronegative gas in the GM chamber working gas on the observed characteristics was also analyzed. The obtained results differ drastically from the results of similar tests presented in previously published papers on similar topics. This result is explained by the fact that the law of similarity for gas emissions was taken into consideration when making the tested tubes (i.e., the mean free path length of the electron was treated as a geometric parameter). In that way, the relevant results for the application of GM counters in practice were obtained. The result obtained with a small percentage of electronegative gas in the three-component mixture of gases noble gas + quenching gas + electronegative gas confirms the positive synergistic effect of the electronegative gas addition. This result contradicts the general view that GM chamber working gas must not contain electronegative gas. PB - Pergamon-Elsevier Science Ltd, Oxford T2 - Vacuum T1 - The influence of the GM tube insulation parameters on the GM counter characteristics VL - 196 DO - 10.1016/j.vacuum.2021.110755 ER -
@article{ author = "Arbutina, Dalibor and Vasić-Milovanović, Aleksandra and Nedić, Teodora M.", year = "2022", abstract = "The paper presents the results of testing the Geiger-Muller chamber cathode radii on the GM counters characteristics. The influence of the cathode radius is tested on: 1 - the GM counter characteristic; 2 - the length and plateau slope; and 3 - the GM counter chamber lifetime. The influence of small amounts of electronegative gas in the GM chamber working gas on the observed characteristics was also analyzed. The obtained results differ drastically from the results of similar tests presented in previously published papers on similar topics. This result is explained by the fact that the law of similarity for gas emissions was taken into consideration when making the tested tubes (i.e., the mean free path length of the electron was treated as a geometric parameter). In that way, the relevant results for the application of GM counters in practice were obtained. The result obtained with a small percentage of electronegative gas in the three-component mixture of gases noble gas + quenching gas + electronegative gas confirms the positive synergistic effect of the electronegative gas addition. This result contradicts the general view that GM chamber working gas must not contain electronegative gas.", publisher = "Pergamon-Elsevier Science Ltd, Oxford", journal = "Vacuum", title = "The influence of the GM tube insulation parameters on the GM counter characteristics", volume = "196", doi = "10.1016/j.vacuum.2021.110755" }
Arbutina, D., Vasić-Milovanović, A.,& Nedić, T. M.. (2022). The influence of the GM tube insulation parameters on the GM counter characteristics. in Vacuum Pergamon-Elsevier Science Ltd, Oxford., 196. https://doi.org/10.1016/j.vacuum.2021.110755
Arbutina D, Vasić-Milovanović A, Nedić TM. The influence of the GM tube insulation parameters on the GM counter characteristics. in Vacuum. 2022;196. doi:10.1016/j.vacuum.2021.110755 .
Arbutina, Dalibor, Vasić-Milovanović, Aleksandra, Nedić, Teodora M., "The influence of the GM tube insulation parameters on the GM counter characteristics" in Vacuum, 196 (2022), https://doi.org/10.1016/j.vacuum.2021.110755 . .