Faktori sigurnosti u proračunu debljine zida kolona za rektifikaciju
Safety factors in wall thickness calculation of rectification columns
2021
Authors
Petronić, SanjaČolić, Katarina
Jarić, Marko
Ćurčić, Nebojša
Burzić, Zijah
Sofijanić, Svetozar
Article (Published version)
Metadata
Show full item recordAbstract
Kolone za rektifikaciju gasa veoma su važan deo svake fabrike. Njihovi iznenadni otkazi svakodnevno uzrokuju ogromne gubitke, dok curenje tečnosti može biti veoma opasno po ljude i životnu sredinu. Iz tog razloga, pravilan dizajn kolone je od velike važnosti, kao i primena ostalih faktora bezbednosti. U ovom radu prikazano je merenje debljine zida sa ciljem da se izračuna stopa korozije i preostali vek trajanja rektifikacionih kolona. Minimalna potrebna debljina zida kolone izračunata je prema najčešće korišćenim međunarodnim standardima i analizirana je dobijena razlika.
Gas rectification columns are a very important part of each onshore plant. Their sudden failures cause huge losses on a daily basis, while fluid leakage can be very dangerous to people and environment. For that reason, the proper design of the column is of huge importance, among the others safety factors as well. In this paper, the wall thickness measure is presented with the aim to calculate corrosion rate and remaining life of rectification columns. The minimum required column wall thickness was calculated according to the most commonly used international standard and the obtained difference was analyzed.
Keywords:
stopa korozije / preostali vek trajanja / kolone za rektifikaciju gasa / IBR / faktori bezbednosti / debljina / thickness / safety factors / remaining life / NDT / gas rectification columns / corrosion rateSource:
Scientific Technical Review, 2021, 71, 1, 3-7Publisher:
- Vojnotehnički institut, Beograd
Funding / projects:
- Ministry of Science, Technological Development and Innovation of the Republic of Serbia, institutional funding - 200105 (University of Belgrade, Faculty of Mechanical Engineering) (RS-MESTD-inst-2020-200105)
Collections
Institution/Community
Inovacioni centarTY - JOUR AU - Petronić, Sanja AU - Čolić, Katarina AU - Jarić, Marko AU - Ćurčić, Nebojša AU - Burzić, Zijah AU - Sofijanić, Svetozar PY - 2021 UR - https://machinery.mas.bg.ac.rs/handle/123456789/3506 AB - Kolone za rektifikaciju gasa veoma su važan deo svake fabrike. Njihovi iznenadni otkazi svakodnevno uzrokuju ogromne gubitke, dok curenje tečnosti može biti veoma opasno po ljude i životnu sredinu. Iz tog razloga, pravilan dizajn kolone je od velike važnosti, kao i primena ostalih faktora bezbednosti. U ovom radu prikazano je merenje debljine zida sa ciljem da se izračuna stopa korozije i preostali vek trajanja rektifikacionih kolona. Minimalna potrebna debljina zida kolone izračunata je prema najčešće korišćenim međunarodnim standardima i analizirana je dobijena razlika. AB - Gas rectification columns are a very important part of each onshore plant. Their sudden failures cause huge losses on a daily basis, while fluid leakage can be very dangerous to people and environment. For that reason, the proper design of the column is of huge importance, among the others safety factors as well. In this paper, the wall thickness measure is presented with the aim to calculate corrosion rate and remaining life of rectification columns. The minimum required column wall thickness was calculated according to the most commonly used international standard and the obtained difference was analyzed. PB - Vojnotehnički institut, Beograd T2 - Scientific Technical Review T1 - Faktori sigurnosti u proračunu debljine zida kolona za rektifikaciju T1 - Safety factors in wall thickness calculation of rectification columns EP - 7 IS - 1 SP - 3 VL - 71 DO - 10.5937/str2101003P ER -
@article{ author = "Petronić, Sanja and Čolić, Katarina and Jarić, Marko and Ćurčić, Nebojša and Burzić, Zijah and Sofijanić, Svetozar", year = "2021", abstract = "Kolone za rektifikaciju gasa veoma su važan deo svake fabrike. Njihovi iznenadni otkazi svakodnevno uzrokuju ogromne gubitke, dok curenje tečnosti može biti veoma opasno po ljude i životnu sredinu. Iz tog razloga, pravilan dizajn kolone je od velike važnosti, kao i primena ostalih faktora bezbednosti. U ovom radu prikazano je merenje debljine zida sa ciljem da se izračuna stopa korozije i preostali vek trajanja rektifikacionih kolona. Minimalna potrebna debljina zida kolone izračunata je prema najčešće korišćenim međunarodnim standardima i analizirana je dobijena razlika., Gas rectification columns are a very important part of each onshore plant. Their sudden failures cause huge losses on a daily basis, while fluid leakage can be very dangerous to people and environment. For that reason, the proper design of the column is of huge importance, among the others safety factors as well. In this paper, the wall thickness measure is presented with the aim to calculate corrosion rate and remaining life of rectification columns. The minimum required column wall thickness was calculated according to the most commonly used international standard and the obtained difference was analyzed.", publisher = "Vojnotehnički institut, Beograd", journal = "Scientific Technical Review", title = "Faktori sigurnosti u proračunu debljine zida kolona za rektifikaciju, Safety factors in wall thickness calculation of rectification columns", pages = "7-3", number = "1", volume = "71", doi = "10.5937/str2101003P" }
Petronić, S., Čolić, K., Jarić, M., Ćurčić, N., Burzić, Z.,& Sofijanić, S.. (2021). Faktori sigurnosti u proračunu debljine zida kolona za rektifikaciju. in Scientific Technical Review Vojnotehnički institut, Beograd., 71(1), 3-7. https://doi.org/10.5937/str2101003P
Petronić S, Čolić K, Jarić M, Ćurčić N, Burzić Z, Sofijanić S. Faktori sigurnosti u proračunu debljine zida kolona za rektifikaciju. in Scientific Technical Review. 2021;71(1):3-7. doi:10.5937/str2101003P .
Petronić, Sanja, Čolić, Katarina, Jarić, Marko, Ćurčić, Nebojša, Burzić, Zijah, Sofijanić, Svetozar, "Faktori sigurnosti u proračunu debljine zida kolona za rektifikaciju" in Scientific Technical Review, 71, no. 1 (2021):3-7, https://doi.org/10.5937/str2101003P . .