Приказ основних података о документу

dc.creatorArbutina, Dalibor
dc.creatorVasić-Milovanović, Aleksandra
dc.date.accessioned2022-09-19T19:08:19Z
dc.date.available2022-09-19T19:08:19Z
dc.date.issued2020
dc.identifier.issn0018-9499
dc.identifier.urihttps://machinery.mas.bg.ac.rs/handle/123456789/3423
dc.description.abstractThis article considers the influence of the anode (r(a)) and cathode (r(k)) radius dimensions in the Geiger Muller counter chamber on its characteristics such as efficiency, measurement uncertainty, dead time, slope, plateau length, and aging. The article is of a theoretical and experimental nature. In the theoretical part of the article, the expression for the dependence of the electrical discharge parameters of a cylindrical electrode system is derived from various radius dimensions of the anode and cathode. For this purpose, the enlargement law of the probability was applied. The experimental part of the work was performed on the models of the Geiger Muller's chamber of different radius dimensions of the anode and cathode. The chamber models (and insulation gas) were made to maintain the geometrical similarity of the commercially applicable chamber. In the first experimental part of this article, the effect of radioactive radiation was simulated with a fast pulse voltage, while real radioactive elements were used in the second experimental part. The testing has shown that the synergy of the stochastic volume effect of the breakdown voltage of the Ruffer-Kuilling mechanism and the corona of the plasma can significantly improve all tested characteristics.en
dc.publisherIeee-Inst Electrical Electronics Engineers Inc, Piscataway
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/171007/RS//
dc.rightsrestrictedAccess
dc.sourceIeee Transactions on Nuclear Science
dc.subjectRadiation detectorsen
dc.subjectGeiger countersen
dc.subjectElectric fieldsen
dc.subjectElectric breakdownen
dc.subjectDistribution functionsen
dc.subjectDetectorsen
dc.subjectCathodesen
dc.subjectAnodesen
dc.titleImproving the Geiger Muller Counter Characteristics by Optimizing the Anode and Cathode Radius Dimensionsen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage2237
dc.citation.issue10
dc.citation.other67(10): 2231-2237
dc.citation.rankM22
dc.citation.spage2231
dc.citation.volume67
dc.identifier.doi10.1109/TNS.2020.3018785
dc.identifier.scopus2-s2.0-85094166251
dc.identifier.wos000579340700010
dc.type.versionpublishedVersion


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу