Osrednjavanje koeficijenta prelaženja toplote po dužini cevi, pri ustaljenom laminarnom i hidrodinamički stabilizovanom strujanju ulja i drugih tečnosti
Heat transfer coefficient averaging along the pipe length during stable laminar and hydro dynamically stable flow of oil and other liquids
Apstrakt
U predajnicima toplote, pri proračunu toplote, obično se koriste stalne vrednosti koeficijenata prelaženja toplote, koji je osrednjen po dužini kanala. Međutim, to osrednjavanje je ponekad nemoguće ili bez ikakvog fizičkog smisla, na primer, pri posebnim okolnostima sa promenljivom temperaturom na unutrašnjoj površi kanala.
While calculating the heat of heat exchangers, the constant values of heat transfer coefficient are usually used, that is averaged along the duct length. But, this averaging is sometimes impossible, or without any physical meaning, for instance in special circumstances with variable temperature at the inside surface of the channel.
Ključne reči:
temperatura na površi / laminarno strujanje / koeficijent prelaženja toplote / surface temperature / laminar fluid flow / heat transfer coefficientIzvor:
Procesna tehnika, 2002, 18, 3, 9-13Izdavač:
- Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS), Beograd
Kolekcije
Institucija/grupa
Mašinski fakultetTY - JOUR AU - Vasiljević, Bogosav M. AU - Banjac, Miloš PY - 2002 UR - https://machinery.mas.bg.ac.rs/handle/123456789/314 AB - U predajnicima toplote, pri proračunu toplote, obično se koriste stalne vrednosti koeficijenata prelaženja toplote, koji je osrednjen po dužini kanala. Međutim, to osrednjavanje je ponekad nemoguće ili bez ikakvog fizičkog smisla, na primer, pri posebnim okolnostima sa promenljivom temperaturom na unutrašnjoj površi kanala. AB - While calculating the heat of heat exchangers, the constant values of heat transfer coefficient are usually used, that is averaged along the duct length. But, this averaging is sometimes impossible, or without any physical meaning, for instance in special circumstances with variable temperature at the inside surface of the channel. PB - Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS), Beograd T2 - Procesna tehnika T1 - Osrednjavanje koeficijenta prelaženja toplote po dužini cevi, pri ustaljenom laminarnom i hidrodinamički stabilizovanom strujanju ulja i drugih tečnosti T1 - Heat transfer coefficient averaging along the pipe length during stable laminar and hydro dynamically stable flow of oil and other liquids EP - 13 IS - 3 SP - 9 VL - 18 UR - https://hdl.handle.net/21.15107/rcub_machinery_314 ER -
@article{ author = "Vasiljević, Bogosav M. and Banjac, Miloš", year = "2002", abstract = "U predajnicima toplote, pri proračunu toplote, obično se koriste stalne vrednosti koeficijenata prelaženja toplote, koji je osrednjen po dužini kanala. Međutim, to osrednjavanje je ponekad nemoguće ili bez ikakvog fizičkog smisla, na primer, pri posebnim okolnostima sa promenljivom temperaturom na unutrašnjoj površi kanala., While calculating the heat of heat exchangers, the constant values of heat transfer coefficient are usually used, that is averaged along the duct length. But, this averaging is sometimes impossible, or without any physical meaning, for instance in special circumstances with variable temperature at the inside surface of the channel.", publisher = "Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS), Beograd", journal = "Procesna tehnika", title = "Osrednjavanje koeficijenta prelaženja toplote po dužini cevi, pri ustaljenom laminarnom i hidrodinamički stabilizovanom strujanju ulja i drugih tečnosti, Heat transfer coefficient averaging along the pipe length during stable laminar and hydro dynamically stable flow of oil and other liquids", pages = "13-9", number = "3", volume = "18", url = "https://hdl.handle.net/21.15107/rcub_machinery_314" }
Vasiljević, B. M.,& Banjac, M.. (2002). Osrednjavanje koeficijenta prelaženja toplote po dužini cevi, pri ustaljenom laminarnom i hidrodinamički stabilizovanom strujanju ulja i drugih tečnosti. in Procesna tehnika Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS), Beograd., 18(3), 9-13. https://hdl.handle.net/21.15107/rcub_machinery_314
Vasiljević BM, Banjac M. Osrednjavanje koeficijenta prelaženja toplote po dužini cevi, pri ustaljenom laminarnom i hidrodinamički stabilizovanom strujanju ulja i drugih tečnosti. in Procesna tehnika. 2002;18(3):9-13. https://hdl.handle.net/21.15107/rcub_machinery_314 .
Vasiljević, Bogosav M., Banjac, Miloš, "Osrednjavanje koeficijenta prelaženja toplote po dužini cevi, pri ustaljenom laminarnom i hidrodinamički stabilizovanom strujanju ulja i drugih tečnosti" in Procesna tehnika, 18, no. 3 (2002):9-13, https://hdl.handle.net/21.15107/rcub_machinery_314 .