Приказ основних података о документу

dc.creatorJacimović, Nikola
dc.creatorGenić, Srbislav
dc.creatorJaćimović, Branislav M.
dc.date.accessioned2022-09-19T18:44:02Z
dc.date.available2022-09-19T18:44:02Z
dc.date.issued2019
dc.identifier.issn0930-7516
dc.identifier.urihttps://machinery.mas.bg.ac.rs/handle/123456789/3067
dc.description.abstractRemoval of oxygen from feedwater is of paramount importance for safe boiler operation. Insufficient extraction of oxygen in deaeration vessels will lead to limited efficiency of oxygen scavengers and unsafe plant operation. The presented sizing procedure for packed deaeration columns is based on the similarity theory between heat and mass transfer and existing procedures. The goal of the proposed technique is not to achieve optimization of column dimensions, but to ensure that there is no undersizing of the packing height. This approach is justified considering the relatively low capital costs of deaeration columns in boiler plants. The proposed equations are based on an experimental setup involving several hundred operating regimes which have been verified and confirmed to have a high degree of accuracy.en
dc.publisherWiley-V C H Verlag Gmbh, Weinheim
dc.rightsrestrictedAccess
dc.sourceChemical Engineering & Technology
dc.subjectPacked columnsen
dc.subjectDeaeration columnsen
dc.subjectColumn sizingen
dc.subjectBoiler feedwater deaerationen
dc.titleSizing of Packed Deaeration Columnsen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage2716
dc.citation.issue12
dc.citation.other42(12): 2709-2716
dc.citation.rankM21
dc.citation.spage2709
dc.citation.volume42
dc.identifier.doi10.1002/ceat.201800642
dc.identifier.scopus2-s2.0-85073814457
dc.identifier.wos000486667400001
dc.type.versionpublishedVersion