The influence of the gas flowmeter calibration principle on diesel engine particulate emission measurement accuracy

dc.creatorPopović, Slobodan
dc.creatorKnežević, Dragan
dc.creatorPetrović, Stojan
dc.date.accessioned2022-09-19T15:33:28Z
dc.date.available2022-09-19T15:33:28Z
dc.date.issued2002
dc.identifier.issn0354-9496
dc.identifier.urihttps://machinery.mas.bg.ac.rs/handle/123456789/302
dc.description.abstractU radu je prikazan računski postupak za procenu greške određivanja masenog stepena razblaženja uzorka izduvnog gasa i njegovog uticaja na tačnost određivanja ekvivalentnog masenog protoka izduvnog gasa. Na osnovu toga analizirane su tri metode pojedinačne kalibracije masenih termalnih protokomera za gas. Analiza pokazuje da bez obzira na primenjeni princip kalibracije, direktna primena preporuka Pravilnika ECE R49 u domenu određivanja srednjeg masenog stepena razblaženja dovodi do greške u rasponu od ±0.5÷11.0 %, što metodu čini neprihvatljivom. Daljom analizom je obuhvaćena posebna tehnika diferencijalne kalibracije instrumenata za merenje ukupnog protoka razblaženog uzorka gasa i protoka vazduha za razblaženje, čijom se primenom, prema dobijenim rezultatima, greška određivanja srednjeg masenog stepena razblaženja može svesti u granice od 0.2÷0.8 %, dok se greška ekvivalentnog masenog protoka izduvnog gasa zavisno od protoka, kreće u dozvoljenim granicama od 1.1÷1.9 %.sr
dc.description.abstractA numeric procedure for the estimation of the accuracy of diesel engine particulate emission measurement has been presented in this paper. The analysis has been provided for mass dilution ratio (DRmass) and equivalent exhaust mass flow (GEDF) regarding the particulate emission measurement based on gravimetric principle with the Partial-Flow Dilution System with heated micro-tunnel and particulate Total Sampling (PFDS-TS Type, accord. to ECE R.49 and ISO 8178). The analysis has been applied to the measurement of the air dilution (GDIL) and total diluted gas sample (GTOT) mass flows provided by means of thermal mass flow meters. Three basic flow meters calibration principles have been analyzed too. According to the results, the recommendations from ECE R49, if strictly applied, lead to the mass dilution ratio error of ±0.5÷11.0 %, which is much beyond proposed limits, making this method unacceptable. The thermal mass flow meters differential calibration procedure has been analyzed, and as a result, increased accuracy of mass dilution ratio (0.2÷0.8 %) and that of equivalent exhaust mass flow (1.1÷1.9 %) has been reported.en
dc.publisherNaučno društvo za pogonske mašine, traktore i održavanje, Novi Sad i Univerzitet u Novom Sadu - Poljoprivredni fakultet - Institut za poljoprivrednu tehniku, Novi Sad
dc.rightsopenAccess
dc.sourceTraktori i pogonske mašine
dc.subjectmikro-tunelsr
dc.subjectkalibracijasr
dc.subjectgreška merenjasr
dc.subjectemisija česticasr
dc.subjectdizel motorsr
dc.subjectparticulate emissionen
dc.subjectmicro-tunnelen
dc.subjectdiesel engineen
dc.subjectcalibrationen
dc.subjectaccuracyen
dc.titleAnaliza uticaja kalibracije protokomera za gas na tačnost određivanja emisije čestica dizel motorasr
dc.titleThe influence of the gas flowmeter calibration principle on diesel engine particulate emission measurement accuracyen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage42
dc.citation.issue2
dc.citation.other7(2): 36-42
dc.citation.rankM53
dc.citation.spage36
dc.citation.volume7
dc.identifier.fulltexthttp://machinery.mas.bg.ac.rs/bitstream/id/1677/299.pdf