dc.description.abstractThe turbine flat cover pipe (dimension phi 219.1x12.7 mm, and material STPG-38) is tested and cracks are found. Determination of the required wall thickness for a pipe exposed to internal pressure is done according to EN 13480: 3-2012. An analytically determined stress intensity factor for the analysed crack is compared with the critical value of the stress intensity factor to assess the integrity of the analysed structure.en
dc.publisherInstitut za ispitivanje materijala, Beograd
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceStructural Integrity and Life
dc.subjectturbine flat cover pipeen
dc.subjectstructural integrityen
dc.subjectstress intensity factoren
dc.subjectpipe wall thickness calculationen
dc.titleIntegrity assessment of turbine flat cover pipeen
dc.typearticle
dc.rights.licenseBY-NC-ND
dc.citation.epage183
dc.citation.issue3
dc.citation.other18(3): 181-183
dc.citation.rankM24
dc.citation.spage181
dc.citation.volume18
dc.identifier.fulltexthttp://machinery.mas.bg.ac.rs/bitstream/id/1641/2945.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_machinery_2948
dc.identifier.scopus2-s2.0-85063901983
dc.identifier.wos000454668900004
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу