Приказ основних података о документу

dc.creatorGenić, Srbislav
dc.creatorJaćimović, Branislav M.
dc.creatorMilovančević, Uroš
dc.creatorIvošević, Miloš
dc.creatorOtović, Milena
dc.creatorAntić, Milan I.
dc.date.accessioned2022-09-19T18:35:32Z
dc.date.available2022-09-19T18:35:32Z
dc.date.issued2018
dc.identifier.issn0947-7411
dc.identifier.urihttps://machinery.mas.bg.ac.rs/handle/123456789/2941
dc.description.abstractThe procedure for field testing of plate heat exchanger, considered as a black box, is presented in the paper. After the field measurements have been conducted, simple but unambiguous procedure has been used to establish heat performance parameters including the heat duty and fouling factor. Advantage of hereby presented method is that it can be used for analysis of any other similar heat transfer equipment.en
dc.publisherSpringer, New York
dc.relationMinistry of Education, Science and Technological Development of Republic of Serbia
dc.rightsrestrictedAccess
dc.sourceHeat and Mass Transfer
dc.titleThermal performances of a "black box" heat exchanger in district heating systemen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage873
dc.citation.issue3
dc.citation.other54(3): 867-873
dc.citation.rankM22
dc.citation.spage867
dc.citation.volume54
dc.identifier.doi10.1007/s00231-017-2182-5
dc.identifier.scopus2-s2.0-85031403547
dc.identifier.wos000424879600021
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу