dc.description.abstractThe integrity of the ammonia spherical tank (with a volume of 1800 m3 and the outer diameter of 15120 mm, nominal wall thickness 30 mm) was analyzed due to discovered cracks on the longitudinal and transverse but joints of the segments, of different lengths and depth. The calculation according to EN 13445-3: 2014 specifies the minimum required spherical shell wall thickness. The finite element method was used to analyze the cracks and determine the hoop stress value. The stress intensity factor for the analysed cracks was analytically determined, and the obtained values were compared with the critical value of the stress intensity factor to assess the integrity of the observed structure.en
dc.publisherElsevier Science Bv, Amsterdam
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceProcedia Structural Integrity - ECF22 - Loading and environmental effects on structural integrity
dc.subjectstructure integrityen
dc.subjectstress intensity factoren
dc.subjectspherical tanken
dc.subjectfinite element methoden
dc.subjectcalculation of spherical shell wall thicknessen
dc.titleIntegrity assessment of ammonia spherical storage tanken
dc.typeconferenceObject
dc.rights.licenseBY-NC-ND
dc.citation.epage999
dc.citation.other13: 994-999
dc.citation.spage994
dc.citation.volume13
dc.identifier.doi10.1016/j.prostr.2018.12.185
dc.identifier.fulltexthttp://machinery.mas.bg.ac.rs/bitstream/id/1502/2801.pdf
dc.identifier.scopus2-s2.0-85064628334
dc.identifier.wos000459860900162
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу