Analysis of operation of the condenser in a 120 mw thermal power plant
Апстракт
The condenser plant has a huge impact on the economy of a steam turbine power plant. Deterioration of the parameters during operation could lead to a significant decrease in electrical output and to an increase in the heat rate of the thermal power plant. Detailed calculations of the performance under different operating conditions were carried out for the condenser of the Morava thermal power plant. Comprehensive testing of the condenser was carried out and experimental data were compared with the numerical results. The effects of deviations in the condenser behavior on the main thermodynamic parameters and the overall economics of the power plant were evaluated. Guidelines for operation of condensation plants are given in the conclusion.
Кључне речи:
testing / steam power plant / heat rate / condenser / condensation pressureИзвор:
Thermal Science, 2018, 22, 1, 735-746Издавач:
- Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd
DOI: 10.2298/TSCI170903242M
ISSN: 0354-9836
WoS: 000429384500034
Scopus: 2-s2.0-85045340570
Колекције
Институција/група
Mašinski fakultetTY - JOUR AU - Milić, Srđan AU - Petrović, Milan AU - Banjac, Milan AU - Đukanović, Dejan AU - Nedeljković, Srećko PY - 2018 UR - https://machinery.mas.bg.ac.rs/handle/123456789/2800 AB - The condenser plant has a huge impact on the economy of a steam turbine power plant. Deterioration of the parameters during operation could lead to a significant decrease in electrical output and to an increase in the heat rate of the thermal power plant. Detailed calculations of the performance under different operating conditions were carried out for the condenser of the Morava thermal power plant. Comprehensive testing of the condenser was carried out and experimental data were compared with the numerical results. The effects of deviations in the condenser behavior on the main thermodynamic parameters and the overall economics of the power plant were evaluated. Guidelines for operation of condensation plants are given in the conclusion. PB - Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd T2 - Thermal Science T1 - Analysis of operation of the condenser in a 120 mw thermal power plant EP - 746 IS - 1 SP - 735 VL - 22 DO - 10.2298/TSCI170903242M ER -
@article{ author = "Milić, Srđan and Petrović, Milan and Banjac, Milan and Đukanović, Dejan and Nedeljković, Srećko", year = "2018", abstract = "The condenser plant has a huge impact on the economy of a steam turbine power plant. Deterioration of the parameters during operation could lead to a significant decrease in electrical output and to an increase in the heat rate of the thermal power plant. Detailed calculations of the performance under different operating conditions were carried out for the condenser of the Morava thermal power plant. Comprehensive testing of the condenser was carried out and experimental data were compared with the numerical results. The effects of deviations in the condenser behavior on the main thermodynamic parameters and the overall economics of the power plant were evaluated. Guidelines for operation of condensation plants are given in the conclusion.", publisher = "Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd", journal = "Thermal Science", title = "Analysis of operation of the condenser in a 120 mw thermal power plant", pages = "746-735", number = "1", volume = "22", doi = "10.2298/TSCI170903242M" }
Milić, S., Petrović, M., Banjac, M., Đukanović, D.,& Nedeljković, S.. (2018). Analysis of operation of the condenser in a 120 mw thermal power plant. in Thermal Science Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd., 22(1), 735-746. https://doi.org/10.2298/TSCI170903242M
Milić S, Petrović M, Banjac M, Đukanović D, Nedeljković S. Analysis of operation of the condenser in a 120 mw thermal power plant. in Thermal Science. 2018;22(1):735-746. doi:10.2298/TSCI170903242M .
Milić, Srđan, Petrović, Milan, Banjac, Milan, Đukanović, Dejan, Nedeljković, Srećko, "Analysis of operation of the condenser in a 120 mw thermal power plant" in Thermal Science, 22, no. 1 (2018):735-746, https://doi.org/10.2298/TSCI170903242M . .