This paper presents experimental results concerning the distribution of the refrigerant R134a in the inlet header of plate evaporators in automotive air-conditioning systems, as a function of operating conditions. Typical conditions in such air-conditioning systems cover the: mass flow rates of 20-60 g/s, and inlet vapor quality at the inlet header of up to 30%. The distribution of the refrigerant is expressed as the fraction of the liquid available at the inlet. The distribution results are given with flow images (shown in the paper) followed by analysis and discussions of the results.
Извор:
SAE Technical Papers, 2002Издавач:
- SAE International
Колекције
Институција/група
Mašinski fakultetTY - CONF AU - Fei, P. AU - Čantrak, Đorđe AU - Hrnjak, P. PY - 2002 UR - https://machinery.mas.bg.ac.rs/handle/123456789/252 AB - This paper presents experimental results concerning the distribution of the refrigerant R134a in the inlet header of plate evaporators in automotive air-conditioning systems, as a function of operating conditions. Typical conditions in such air-conditioning systems cover the: mass flow rates of 20-60 g/s, and inlet vapor quality at the inlet header of up to 30%. The distribution of the refrigerant is expressed as the fraction of the liquid available at the inlet. The distribution results are given with flow images (shown in the paper) followed by analysis and discussions of the results. PB - SAE International C3 - SAE Technical Papers T1 - Refrigerant distribution in the inlet header of plate evaporators DO - 10.4271/2002-01-0948 ER -
@conference{ author = "Fei, P. and Čantrak, Đorđe and Hrnjak, P.", year = "2002", abstract = "This paper presents experimental results concerning the distribution of the refrigerant R134a in the inlet header of plate evaporators in automotive air-conditioning systems, as a function of operating conditions. Typical conditions in such air-conditioning systems cover the: mass flow rates of 20-60 g/s, and inlet vapor quality at the inlet header of up to 30%. The distribution of the refrigerant is expressed as the fraction of the liquid available at the inlet. The distribution results are given with flow images (shown in the paper) followed by analysis and discussions of the results.", publisher = "SAE International", journal = "SAE Technical Papers", title = "Refrigerant distribution in the inlet header of plate evaporators", doi = "10.4271/2002-01-0948" }
Fei, P., Čantrak, Đ.,& Hrnjak, P.. (2002). Refrigerant distribution in the inlet header of plate evaporators. in SAE Technical Papers SAE International.. https://doi.org/10.4271/2002-01-0948
Fei P, Čantrak Đ, Hrnjak P. Refrigerant distribution in the inlet header of plate evaporators. in SAE Technical Papers. 2002;. doi:10.4271/2002-01-0948 .
Fei, P., Čantrak, Đorđe, Hrnjak, P., "Refrigerant distribution in the inlet header of plate evaporators" in SAE Technical Papers (2002), https://doi.org/10.4271/2002-01-0948 . .