dc.description.abstractThe purpose of this paper is to present a case of an office building and show how different concepts of envelope construction affect the energy efficiency of building. Assessment of energy performances of different scenarios of the hypothetical models of the office building in the central zone of Belgrade is the aim of this research. A few scenarios are created for each hypothetical model: basic scenario and scenarios of two shading devices types in order contribution to reduction of cooling demands to be estimated. The office building scenarios are modelled and analysed by using PHPP'2007 software to estimate heat and cooling energy demands. Also, CO2 emissions are discussed. Comparative analysis of the results highlights the advantages and disadvantages of the treated models and scenarios of office building envelope construction. Findings indicate the preferable solutions and highlight methodological approach in the office building envelope design, which has not yet been adopted extensively in practice in our country. Methodological approach and findings can generally be applicable for new office building design, both in Belgrade and in the similar climatic conditions. The paper demonstrates various feasible solutions of office building envelope construction that might help comply with the regulation.en
dc.publisherElsevier Science Sa, Lausanne
dc.relationinfo:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/36035/RS//
dc.rightsrestrictedAccess
dc.sourceEnergy and Buildings
dc.subjectOffice building designen
dc.subjectNumerical simulations of energy efficiencyen
dc.subjectHeat and cooling energy demandsen
dc.subjectEnergy efficiencyen
dc.subjectCO2 emissionsen
dc.titleAssessment of energy and environmental performance of office building models: A case studyen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage22
dc.citation.other115: 11-22
dc.citation.rankaM21
dc.citation.spage11
dc.citation.volume115
dc.identifier.doi10.1016/j.enbuild.2015.06.050
dc.identifier.scopus2-s2.0-84937124404
dc.identifier.wos000373750300003
dc.type.versionpublishedVersion


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record