Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler
Само за регистроване кориснике
2015
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The European normatives prescribe content of 200 mg/Nm(3) NO for pulverized coal combusting power plants. In order to reduce content of NOx in Serbian thermal power plant (TPP) square Kostolac B square it's necessary to implement particular measures until 2016. The mathematical model of lignite combustion in the steam boiler furnace is defined and applied to analyze the possibility of implementing certain primary measures for reducing nitrogen oxides and their effects on the steam boiler operation. This model includes processes in the coal-fired furnace and defines radiating reactive two-phase turbulent flow. The model of turbulent flow also contains sub-model of fuel and thermal NOx formation and destruction. This complex mathematical model is related to thermal and aerodynamic calculations of the steam boiler within a unified calculation system in order to analyze the steam boiler overall work. This system provides calculations with a number of influential parameters. The steam boile...r calculations for unit 1 (350 MWe) of TPP square Kostolac B square are implemented for existing and modified combustion system in order to achieve effective, reliable and ecological facility work. The paper presents the influence analysis of large number of parameters on the steam boiler operation with an accepted concept of primary measures. Presented system of calculations is verified against measurements in TPP square Kostolac B square.
Кључне речи:
Steam boiler / Primary measures / NOx / Mathematical model / Efficiency / Calculation systemИзвор:
Applied Thermal Engineering, 2015, 78, 397-409Издавач:
- Pergamon-Elsevier Science Ltd, Oxford
Финансирање / пројекти:
- Повећање енергетске и еколошке ефикасности процеса у ложишту за угљени прах и оптимизација излазне грејне површине енергетског парног котла применом сопствених софтверских алата (RS-MESTD-Technological Development (TD or TR)-33018)
- Electric Power Industry of Serbia
DOI: 10.1016/j.applthermaleng.2014.12.074
ISSN: 1359-4311
WoS: 000350096700039
Scopus: 2-s2.0-84921480030
Институција/група
Inovacioni centarTY - JOUR AU - Stupar, Goran AU - Tucaković, Dragan AU - Živanović, Titoslav AU - Belošević, Srđan V. PY - 2015 UR - https://machinery.mas.bg.ac.rs/handle/123456789/2190 AB - The European normatives prescribe content of 200 mg/Nm(3) NO for pulverized coal combusting power plants. In order to reduce content of NOx in Serbian thermal power plant (TPP) square Kostolac B square it's necessary to implement particular measures until 2016. The mathematical model of lignite combustion in the steam boiler furnace is defined and applied to analyze the possibility of implementing certain primary measures for reducing nitrogen oxides and their effects on the steam boiler operation. This model includes processes in the coal-fired furnace and defines radiating reactive two-phase turbulent flow. The model of turbulent flow also contains sub-model of fuel and thermal NOx formation and destruction. This complex mathematical model is related to thermal and aerodynamic calculations of the steam boiler within a unified calculation system in order to analyze the steam boiler overall work. This system provides calculations with a number of influential parameters. The steam boiler calculations for unit 1 (350 MWe) of TPP square Kostolac B square are implemented for existing and modified combustion system in order to achieve effective, reliable and ecological facility work. The paper presents the influence analysis of large number of parameters on the steam boiler operation with an accepted concept of primary measures. Presented system of calculations is verified against measurements in TPP square Kostolac B square. PB - Pergamon-Elsevier Science Ltd, Oxford T2 - Applied Thermal Engineering T1 - Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler EP - 409 SP - 397 VL - 78 DO - 10.1016/j.applthermaleng.2014.12.074 ER -
@article{ author = "Stupar, Goran and Tucaković, Dragan and Živanović, Titoslav and Belošević, Srđan V.", year = "2015", abstract = "The European normatives prescribe content of 200 mg/Nm(3) NO for pulverized coal combusting power plants. In order to reduce content of NOx in Serbian thermal power plant (TPP) square Kostolac B square it's necessary to implement particular measures until 2016. The mathematical model of lignite combustion in the steam boiler furnace is defined and applied to analyze the possibility of implementing certain primary measures for reducing nitrogen oxides and their effects on the steam boiler operation. This model includes processes in the coal-fired furnace and defines radiating reactive two-phase turbulent flow. The model of turbulent flow also contains sub-model of fuel and thermal NOx formation and destruction. This complex mathematical model is related to thermal and aerodynamic calculations of the steam boiler within a unified calculation system in order to analyze the steam boiler overall work. This system provides calculations with a number of influential parameters. The steam boiler calculations for unit 1 (350 MWe) of TPP square Kostolac B square are implemented for existing and modified combustion system in order to achieve effective, reliable and ecological facility work. The paper presents the influence analysis of large number of parameters on the steam boiler operation with an accepted concept of primary measures. Presented system of calculations is verified against measurements in TPP square Kostolac B square.", publisher = "Pergamon-Elsevier Science Ltd, Oxford", journal = "Applied Thermal Engineering", title = "Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler", pages = "409-397", volume = "78", doi = "10.1016/j.applthermaleng.2014.12.074" }
Stupar, G., Tucaković, D., Živanović, T.,& Belošević, S. V.. (2015). Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler. in Applied Thermal Engineering Pergamon-Elsevier Science Ltd, Oxford., 78, 397-409. https://doi.org/10.1016/j.applthermaleng.2014.12.074
Stupar G, Tucaković D, Živanović T, Belošević SV. Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler. in Applied Thermal Engineering. 2015;78:397-409. doi:10.1016/j.applthermaleng.2014.12.074 .
Stupar, Goran, Tucaković, Dragan, Živanović, Titoslav, Belošević, Srđan V., "Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler" in Applied Thermal Engineering, 78 (2015):397-409, https://doi.org/10.1016/j.applthermaleng.2014.12.074 . .