The paper presents the designing process of the passive micromixer. Design parameters of microfluidic channel's geometry are optimized based on flow simulation results. CAD software Solid Works and application Flo Xpress are used for designing and simulation. Aim of presented student's work is not connected to any actual research activities. However part of MSc Thesis shows outcome of student's ability that is accomplished at Biomedical department. This is one of outcomes of BioEMIS TEMPUS project, and therefore the future work on this topic regarding practical implementation is not given here.
Ključne reči:
Simulation / Passive Micromixer / Optimization / DesignIzvor:
Proceedings - 2015 4th Mediterranean Conference on Embedded Computing, MECO 2015 - Including ECyPS 2, 2015, 395-398Izdavač:
- Institute of Electrical and Electronics Engineers Inc.
Finansiranje / projekti:
- Funkcionalizacija nanomaterijala za dobijanje nove vrste kontaktnih sočiva i ranu detekciju dijabetesa (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-45009)
Kolekcije
Institucija/grupa
Mašinski fakultetTY - CONF AU - Ranković, Siniša AU - Bojović, Božica PY - 2015 UR - https://machinery.mas.bg.ac.rs/handle/123456789/2130 AB - The paper presents the designing process of the passive micromixer. Design parameters of microfluidic channel's geometry are optimized based on flow simulation results. CAD software Solid Works and application Flo Xpress are used for designing and simulation. Aim of presented student's work is not connected to any actual research activities. However part of MSc Thesis shows outcome of student's ability that is accomplished at Biomedical department. This is one of outcomes of BioEMIS TEMPUS project, and therefore the future work on this topic regarding practical implementation is not given here. PB - Institute of Electrical and Electronics Engineers Inc. C3 - Proceedings - 2015 4th Mediterranean Conference on Embedded Computing, MECO 2015 - Including ECyPS 2 T1 - An example of passive micromixer design, simulation and optimization EP - 398 SP - 395 DO - 10.1109/MECO.2015.7181953 ER -
@conference{ author = "Ranković, Siniša and Bojović, Božica", year = "2015", abstract = "The paper presents the designing process of the passive micromixer. Design parameters of microfluidic channel's geometry are optimized based on flow simulation results. CAD software Solid Works and application Flo Xpress are used for designing and simulation. Aim of presented student's work is not connected to any actual research activities. However part of MSc Thesis shows outcome of student's ability that is accomplished at Biomedical department. This is one of outcomes of BioEMIS TEMPUS project, and therefore the future work on this topic regarding practical implementation is not given here.", publisher = "Institute of Electrical and Electronics Engineers Inc.", journal = "Proceedings - 2015 4th Mediterranean Conference on Embedded Computing, MECO 2015 - Including ECyPS 2", title = "An example of passive micromixer design, simulation and optimization", pages = "398-395", doi = "10.1109/MECO.2015.7181953" }
Ranković, S.,& Bojović, B.. (2015). An example of passive micromixer design, simulation and optimization. in Proceedings - 2015 4th Mediterranean Conference on Embedded Computing, MECO 2015 - Including ECyPS 2 Institute of Electrical and Electronics Engineers Inc.., 395-398. https://doi.org/10.1109/MECO.2015.7181953
Ranković S, Bojović B. An example of passive micromixer design, simulation and optimization. in Proceedings - 2015 4th Mediterranean Conference on Embedded Computing, MECO 2015 - Including ECyPS 2. 2015;:395-398. doi:10.1109/MECO.2015.7181953 .
Ranković, Siniša, Bojović, Božica, "An example of passive micromixer design, simulation and optimization" in Proceedings - 2015 4th Mediterranean Conference on Embedded Computing, MECO 2015 - Including ECyPS 2 (2015):395-398, https://doi.org/10.1109/MECO.2015.7181953 . .