An Example of Passive Micromixer Design, Simulation and Optimization Biomedical engineering MSc Thesis
Апстракт
The paper presents the designing process of the passive micromixer. Design parameters of microfluidic channel's geometry are optimized based on flow simulation results. CAD software Solid Works and application Flo Xpress are used for designing and simulation. Aim of presented student's work is not connected to any actual research activities. However part of MSc Thesis shows outcome of student's ability that is accomplished at Biomedical department. This is one of outcomes of BioEMIS TEMPUS project, and therefore the future work on this topic regarding practical implementation is not given here.
Кључне речи:
Simulation / Passive Micromixer / Optimization / DesignИзвор:
2015 4th Mediterranean Conference on Embedded Computing (Meco), 2015, 395-398Издавач:
- IEEE, New York
Колекције
Институција/група
Mašinski fakultetTY - CONF AU - Ranković, Siniša AU - Bojović, Božica PY - 2015 UR - https://machinery.mas.bg.ac.rs/handle/123456789/2105 AB - The paper presents the designing process of the passive micromixer. Design parameters of microfluidic channel's geometry are optimized based on flow simulation results. CAD software Solid Works and application Flo Xpress are used for designing and simulation. Aim of presented student's work is not connected to any actual research activities. However part of MSc Thesis shows outcome of student's ability that is accomplished at Biomedical department. This is one of outcomes of BioEMIS TEMPUS project, and therefore the future work on this topic regarding practical implementation is not given here. PB - IEEE, New York C3 - 2015 4th Mediterranean Conference on Embedded Computing (Meco) T1 - An Example of Passive Micromixer Design, Simulation and Optimization Biomedical engineering MSc Thesis EP - 398 SP - 395 UR - https://hdl.handle.net/21.15107/rcub_machinery_2105 ER -
@conference{ author = "Ranković, Siniša and Bojović, Božica", year = "2015", abstract = "The paper presents the designing process of the passive micromixer. Design parameters of microfluidic channel's geometry are optimized based on flow simulation results. CAD software Solid Works and application Flo Xpress are used for designing and simulation. Aim of presented student's work is not connected to any actual research activities. However part of MSc Thesis shows outcome of student's ability that is accomplished at Biomedical department. This is one of outcomes of BioEMIS TEMPUS project, and therefore the future work on this topic regarding practical implementation is not given here.", publisher = "IEEE, New York", journal = "2015 4th Mediterranean Conference on Embedded Computing (Meco)", title = "An Example of Passive Micromixer Design, Simulation and Optimization Biomedical engineering MSc Thesis", pages = "398-395", url = "https://hdl.handle.net/21.15107/rcub_machinery_2105" }
Ranković, S.,& Bojović, B.. (2015). An Example of Passive Micromixer Design, Simulation and Optimization Biomedical engineering MSc Thesis. in 2015 4th Mediterranean Conference on Embedded Computing (Meco) IEEE, New York., 395-398. https://hdl.handle.net/21.15107/rcub_machinery_2105
Ranković S, Bojović B. An Example of Passive Micromixer Design, Simulation and Optimization Biomedical engineering MSc Thesis. in 2015 4th Mediterranean Conference on Embedded Computing (Meco). 2015;:395-398. https://hdl.handle.net/21.15107/rcub_machinery_2105 .
Ranković, Siniša, Bojović, Božica, "An Example of Passive Micromixer Design, Simulation and Optimization Biomedical engineering MSc Thesis" in 2015 4th Mediterranean Conference on Embedded Computing (Meco) (2015):395-398, https://hdl.handle.net/21.15107/rcub_machinery_2105 .