Emisija dimnih gasova pri zavarivanju metalnom punjenom i samozaštitnom žicom
Gas emission during welding with metal cored and self-shielded wire
2015
Аутори
Popović, OliveraProkić-Cvetković, Radica
Lukić, Uroš
Jovičić, Radomir
Burzić, Meri
Beljić, Biljana
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
Punjene i samozaštitne žice su dodatni materijali koji se poslednjih godina sve više koriste zbog povećane produktivnosti i ekonomičnosti, boljeg kvaliteta spoja i lakšeg rada na terenu. S druge strane, jedan od glavnih nedostataka ovih žica je povećana količina dimnih gasova i nedovoljna istraženost njihove štetnosti, naročito u slučaju samozaštitne žice. Zbog toga se pred nove generacije ovih žica postavlja i ekološki zahtev smanjenja emisije dimnih gasova radi zaštite kako zdravlja zavarivača, tako i okoline. U cilju istraživanja ovog uticaja, ploče čelika mikrolegiranog sa V, Nb i Ti su zavarene metalnom punjenom žicom u zaštitnoj atmosferi Ar+5.9%CO2+1.1%O2 i samozaštitnom žicom. Pri tome su izmerene vrednosti emisije gasova CO, CO2 i SO2, kao i ukupne prašine. Dobijene vrednosti su upoređene kako međusobno, tako i sa maksimalnim dozvoljenim koncentracijama prema važećem standardu. Utvrđeno je da samozaštitne žice, suprotno očekivanjima, ne pokazuju veću toksičnost u odnosu na met...alne punjene žice.
The use of flux cored and self-shielded wires as filler materials for gas metal arc welding is growing constantly due to increased productivity and efficiency, better weld quality and easer operation. On the other hand, one of the major drawbacks of these wires is the increased amount of fumes and gases and insufficient data of their harmful effects, especially in the case of self shielded wire. Therefore, in now days, one of the most important requirements is environmentally and health request for decreased fume and gas emission. In this paper, the plates of steel micro alloyed with V, Nb and Ti, were welded with metal cored wire in shielded atmosphere of Ar+5.9%CO2+1.1%O2 and with self-shielded wire. The concentrations of emitted total dust and gases CO, CO2 and SO2 were measured. Obtained values were compared with permissible exposure limits defined by standard. It was estimated that self shielded wire did not show higher toxicity compare to metal cored wire, what is in the contrast... with previous studies.
Кључне речи:
samozaštitna žica / metalna punjena žica / maksimalno dozvoljene koncentracije / emisija / dimni gasovi / self-shielded wire / permissible exposure limits / metal cored wire / fume gases / emissionИзвор:
Zavarivanje i zavarene konstrukcije, 2015, 60, 1, 15-20Издавач:
- DUZS - Društvo za unapređivanje zavarivanja u Srbiji, Beograd
Финансирање / пројекти:
- Истраживање могућности унапређења технологије заваривања микролегираних челика (RS-MESTD-Technological Development (TD or TR)-35024)
Колекције
Институција/група
Mašinski fakultetTY - JOUR AU - Popović, Olivera AU - Prokić-Cvetković, Radica AU - Lukić, Uroš AU - Jovičić, Radomir AU - Burzić, Meri AU - Beljić, Biljana PY - 2015 UR - https://machinery.mas.bg.ac.rs/handle/123456789/2071 AB - Punjene i samozaštitne žice su dodatni materijali koji se poslednjih godina sve više koriste zbog povećane produktivnosti i ekonomičnosti, boljeg kvaliteta spoja i lakšeg rada na terenu. S druge strane, jedan od glavnih nedostataka ovih žica je povećana količina dimnih gasova i nedovoljna istraženost njihove štetnosti, naročito u slučaju samozaštitne žice. Zbog toga se pred nove generacije ovih žica postavlja i ekološki zahtev smanjenja emisije dimnih gasova radi zaštite kako zdravlja zavarivača, tako i okoline. U cilju istraživanja ovog uticaja, ploče čelika mikrolegiranog sa V, Nb i Ti su zavarene metalnom punjenom žicom u zaštitnoj atmosferi Ar+5.9%CO2+1.1%O2 i samozaštitnom žicom. Pri tome su izmerene vrednosti emisije gasova CO, CO2 i SO2, kao i ukupne prašine. Dobijene vrednosti su upoređene kako međusobno, tako i sa maksimalnim dozvoljenim koncentracijama prema važećem standardu. Utvrđeno je da samozaštitne žice, suprotno očekivanjima, ne pokazuju veću toksičnost u odnosu na metalne punjene žice. AB - The use of flux cored and self-shielded wires as filler materials for gas metal arc welding is growing constantly due to increased productivity and efficiency, better weld quality and easer operation. On the other hand, one of the major drawbacks of these wires is the increased amount of fumes and gases and insufficient data of their harmful effects, especially in the case of self shielded wire. Therefore, in now days, one of the most important requirements is environmentally and health request for decreased fume and gas emission. In this paper, the plates of steel micro alloyed with V, Nb and Ti, were welded with metal cored wire in shielded atmosphere of Ar+5.9%CO2+1.1%O2 and with self-shielded wire. The concentrations of emitted total dust and gases CO, CO2 and SO2 were measured. Obtained values were compared with permissible exposure limits defined by standard. It was estimated that self shielded wire did not show higher toxicity compare to metal cored wire, what is in the contrast with previous studies. PB - DUZS - Društvo za unapređivanje zavarivanja u Srbiji, Beograd T2 - Zavarivanje i zavarene konstrukcije T1 - Emisija dimnih gasova pri zavarivanju metalnom punjenom i samozaštitnom žicom T1 - Gas emission during welding with metal cored and self-shielded wire EP - 20 IS - 1 SP - 15 VL - 60 DO - 10.5937/zzk1501015P ER -
@article{ author = "Popović, Olivera and Prokić-Cvetković, Radica and Lukić, Uroš and Jovičić, Radomir and Burzić, Meri and Beljić, Biljana", year = "2015", abstract = "Punjene i samozaštitne žice su dodatni materijali koji se poslednjih godina sve više koriste zbog povećane produktivnosti i ekonomičnosti, boljeg kvaliteta spoja i lakšeg rada na terenu. S druge strane, jedan od glavnih nedostataka ovih žica je povećana količina dimnih gasova i nedovoljna istraženost njihove štetnosti, naročito u slučaju samozaštitne žice. Zbog toga se pred nove generacije ovih žica postavlja i ekološki zahtev smanjenja emisije dimnih gasova radi zaštite kako zdravlja zavarivača, tako i okoline. U cilju istraživanja ovog uticaja, ploče čelika mikrolegiranog sa V, Nb i Ti su zavarene metalnom punjenom žicom u zaštitnoj atmosferi Ar+5.9%CO2+1.1%O2 i samozaštitnom žicom. Pri tome su izmerene vrednosti emisije gasova CO, CO2 i SO2, kao i ukupne prašine. Dobijene vrednosti su upoređene kako međusobno, tako i sa maksimalnim dozvoljenim koncentracijama prema važećem standardu. Utvrđeno je da samozaštitne žice, suprotno očekivanjima, ne pokazuju veću toksičnost u odnosu na metalne punjene žice., The use of flux cored and self-shielded wires as filler materials for gas metal arc welding is growing constantly due to increased productivity and efficiency, better weld quality and easer operation. On the other hand, one of the major drawbacks of these wires is the increased amount of fumes and gases and insufficient data of their harmful effects, especially in the case of self shielded wire. Therefore, in now days, one of the most important requirements is environmentally and health request for decreased fume and gas emission. In this paper, the plates of steel micro alloyed with V, Nb and Ti, were welded with metal cored wire in shielded atmosphere of Ar+5.9%CO2+1.1%O2 and with self-shielded wire. The concentrations of emitted total dust and gases CO, CO2 and SO2 were measured. Obtained values were compared with permissible exposure limits defined by standard. It was estimated that self shielded wire did not show higher toxicity compare to metal cored wire, what is in the contrast with previous studies.", publisher = "DUZS - Društvo za unapređivanje zavarivanja u Srbiji, Beograd", journal = "Zavarivanje i zavarene konstrukcije", title = "Emisija dimnih gasova pri zavarivanju metalnom punjenom i samozaštitnom žicom, Gas emission during welding with metal cored and self-shielded wire", pages = "20-15", number = "1", volume = "60", doi = "10.5937/zzk1501015P" }
Popović, O., Prokić-Cvetković, R., Lukić, U., Jovičić, R., Burzić, M.,& Beljić, B.. (2015). Emisija dimnih gasova pri zavarivanju metalnom punjenom i samozaštitnom žicom. in Zavarivanje i zavarene konstrukcije DUZS - Društvo za unapređivanje zavarivanja u Srbiji, Beograd., 60(1), 15-20. https://doi.org/10.5937/zzk1501015P
Popović O, Prokić-Cvetković R, Lukić U, Jovičić R, Burzić M, Beljić B. Emisija dimnih gasova pri zavarivanju metalnom punjenom i samozaštitnom žicom. in Zavarivanje i zavarene konstrukcije. 2015;60(1):15-20. doi:10.5937/zzk1501015P .
Popović, Olivera, Prokić-Cvetković, Radica, Lukić, Uroš, Jovičić, Radomir, Burzić, Meri, Beljić, Biljana, "Emisija dimnih gasova pri zavarivanju metalnom punjenom i samozaštitnom žicom" in Zavarivanje i zavarene konstrukcije, 60, no. 1 (2015):15-20, https://doi.org/10.5937/zzk1501015P . .