dc.description.abstractTemperature stratification in the exit stream of cooled air from the plate and fin evaporator in automotive air conditioning occurs under low operating loads. Numerical simulations and analyses show that this malfunction is caused by the uneven distribution of the refrigerant liquid from the two-phase mixture in the header towards the evaporating channel. The applied numerical approach is validated for available experimental conditions. Refrigerant two-phase flows in a header of improved design are numerically investigated and a reduction of the temperature stratification is demonstrated.en
dc.publisherWoodhead Publishing Limited
dc.rightsrestrictedAccess
dc.sourceInstitution of Mechanical Engineers - VTMS 2011, Vehicle Thermal Management Systems Conference Proce
dc.titleRefrigerant maldistribution in an evaporator of automotive air conditioning system: investigation and a design improvement by numerical simulationsen
dc.typeconferenceObject
dc.rights.licenseARR
dc.citation.epage112
dc.citation.other: 103-112
dc.citation.spage103
dc.identifier.doi10.1533/9780857094735.2.103
dc.identifier.scopus2-s2.0-84888618954