Приказ основних података о документу

dc.creatorStupar, Goran
dc.creatorTucaković, Dragan
dc.creatorŽivanović, Titoslav
dc.creatorBanjac, M.
dc.creatorBelošević, Srđan V.
dc.creatorBeljanski, Vladimir
dc.creatorTomanović, Ivan
dc.creatorCrnomarković, Nenad
dc.creatorSijerčić, Miroslav
dc.date.accessioned2022-09-19T16:59:57Z
dc.date.available2022-09-19T16:59:57Z
dc.date.issued2012
dc.identifier.urihttps://machinery.mas.bg.ac.rs/handle/123456789/1533
dc.description.abstractWithin Electric Power Utility of Serbia 1991. a thermal power plant "Kostolac B", power 2x350 MW started. Given the increased emissions of NOx in combustion products, it is in consideration to reduce it by introducing primary measures in terms of burner reconstruction, redistribution of secondary air by furnace height and introduction of cold flue gas recirculation. Applying these measures directly affects not only the combustion process in the furnace but also the work efficiency of steam boiler. Namely, if the flue gas temperature in furnace outlet is lowered below the corresponding values, it will cause the superheater and reheater not to achieve the designed steam parameters. On the other hand, the use of cold recirculating flue gases has a beneficial effect on reducing NOx and increases the work safety of the superheaters and reheaters, but reduces the steam boiler efficiency. In order to understand all these effects on the safety and efficiency of boiler operation, it was needed to create a software for thermal calculation of the observed steam boiler. Based on that software, this paper will display the impacts of introducing the measures for reduction of NOx emissions on a safe and efficient operation of the steam boiler as a whole.en
dc.publisherAabo Akademi University
dc.rightsrestrictedAccess
dc.sourceProceedings of the 25th International Conference on Efficiency, Cost, Optimization and Simulation of
dc.subjectSteam boileren
dc.subjectSteam boiler efficiencyen
dc.titleThe influence of primary measures for reducing NOx emissions on energy steam boiler efficiencyen
dc.typeconferenceObject
dc.rights.licenseARR
dc.citation.epage205
dc.citation.other8: 193-205
dc.citation.rankM33
dc.citation.spage193
dc.citation.volume8
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_machinery_1533
dc.identifier.scopus2-s2.0-84896511919
dc.type.versionpublishedVersion


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу