Within Electric Power Utility of Serbia 1991. a thermal power plant "Kostolac B", power 2x350 MW started. Given the increased emissions of NOx in combustion products, it is in consideration to reduce it by introducing primary measures in terms of burner reconstruction, redistribution of secondary air by furnace height and introduction of cold flue gas recirculation. Applying these measures directly affects not only the combustion process in the furnace but also the work efficiency of steam boiler. Namely, if the flue gas temperature in furnace outlet is lowered below the corresponding values, it will cause the superheater and reheater not to achieve the designed steam parameters. On the other hand, the use of cold recirculating flue gases has a beneficial effect on reducing NOx and increases the work safety of the superheaters and reheaters, but reduces the steam boiler efficiency. In order to understand all these effects on the safety and efficiency of boiler operation, it was needed ...to create a software for thermal calculation of the observed steam boiler. Based on that software, this paper will display the impacts of introducing the measures for reduction of NOx emissions on a safe and efficient operation of the steam boiler as a whole.
Кључне речи:
Steam boiler / Steam boiler efficiencyИзвор:
Proceedings of the 25th International Conference on Efficiency, Cost, Optimization and Simulation of, 2012, 8, 193-205Издавач:
- Aabo Akademi University
Scopus: 2-s2.0-84896511919
Институција/група
Inovacioni centarTY - CONF AU - Stupar, Goran AU - Tucaković, Dragan AU - Živanović, Titoslav AU - Banjac, M. AU - Belošević, Srđan V. AU - Beljanski, Vladimir AU - Tomanović, Ivan AU - Crnomarković, Nenad AU - Sijerčić, Miroslav PY - 2012 UR - https://machinery.mas.bg.ac.rs/handle/123456789/1533 AB - Within Electric Power Utility of Serbia 1991. a thermal power plant "Kostolac B", power 2x350 MW started. Given the increased emissions of NOx in combustion products, it is in consideration to reduce it by introducing primary measures in terms of burner reconstruction, redistribution of secondary air by furnace height and introduction of cold flue gas recirculation. Applying these measures directly affects not only the combustion process in the furnace but also the work efficiency of steam boiler. Namely, if the flue gas temperature in furnace outlet is lowered below the corresponding values, it will cause the superheater and reheater not to achieve the designed steam parameters. On the other hand, the use of cold recirculating flue gases has a beneficial effect on reducing NOx and increases the work safety of the superheaters and reheaters, but reduces the steam boiler efficiency. In order to understand all these effects on the safety and efficiency of boiler operation, it was needed to create a software for thermal calculation of the observed steam boiler. Based on that software, this paper will display the impacts of introducing the measures for reduction of NOx emissions on a safe and efficient operation of the steam boiler as a whole. PB - Aabo Akademi University C3 - Proceedings of the 25th International Conference on Efficiency, Cost, Optimization and Simulation of T1 - The influence of primary measures for reducing NOx emissions on energy steam boiler efficiency EP - 205 SP - 193 VL - 8 UR - https://hdl.handle.net/21.15107/rcub_machinery_1533 ER -
@conference{ author = "Stupar, Goran and Tucaković, Dragan and Živanović, Titoslav and Banjac, M. and Belošević, Srđan V. and Beljanski, Vladimir and Tomanović, Ivan and Crnomarković, Nenad and Sijerčić, Miroslav", year = "2012", abstract = "Within Electric Power Utility of Serbia 1991. a thermal power plant "Kostolac B", power 2x350 MW started. Given the increased emissions of NOx in combustion products, it is in consideration to reduce it by introducing primary measures in terms of burner reconstruction, redistribution of secondary air by furnace height and introduction of cold flue gas recirculation. Applying these measures directly affects not only the combustion process in the furnace but also the work efficiency of steam boiler. Namely, if the flue gas temperature in furnace outlet is lowered below the corresponding values, it will cause the superheater and reheater not to achieve the designed steam parameters. On the other hand, the use of cold recirculating flue gases has a beneficial effect on reducing NOx and increases the work safety of the superheaters and reheaters, but reduces the steam boiler efficiency. In order to understand all these effects on the safety and efficiency of boiler operation, it was needed to create a software for thermal calculation of the observed steam boiler. Based on that software, this paper will display the impacts of introducing the measures for reduction of NOx emissions on a safe and efficient operation of the steam boiler as a whole.", publisher = "Aabo Akademi University", journal = "Proceedings of the 25th International Conference on Efficiency, Cost, Optimization and Simulation of", title = "The influence of primary measures for reducing NOx emissions on energy steam boiler efficiency", pages = "205-193", volume = "8", url = "https://hdl.handle.net/21.15107/rcub_machinery_1533" }
Stupar, G., Tucaković, D., Živanović, T., Banjac, M., Belošević, S. V., Beljanski, V., Tomanović, I., Crnomarković, N.,& Sijerčić, M.. (2012). The influence of primary measures for reducing NOx emissions on energy steam boiler efficiency. in Proceedings of the 25th International Conference on Efficiency, Cost, Optimization and Simulation of Aabo Akademi University., 8, 193-205. https://hdl.handle.net/21.15107/rcub_machinery_1533
Stupar G, Tucaković D, Živanović T, Banjac M, Belošević SV, Beljanski V, Tomanović I, Crnomarković N, Sijerčić M. The influence of primary measures for reducing NOx emissions on energy steam boiler efficiency. in Proceedings of the 25th International Conference on Efficiency, Cost, Optimization and Simulation of. 2012;8:193-205. https://hdl.handle.net/21.15107/rcub_machinery_1533 .
Stupar, Goran, Tucaković, Dragan, Živanović, Titoslav, Banjac, M., Belošević, Srđan V., Beljanski, Vladimir, Tomanović, Ivan, Crnomarković, Nenad, Sijerčić, Miroslav, "The influence of primary measures for reducing NOx emissions on energy steam boiler efficiency" in Proceedings of the 25th International Conference on Efficiency, Cost, Optimization and Simulation of, 8 (2012):193-205, https://hdl.handle.net/21.15107/rcub_machinery_1533 .