Estimation of the number of trays for natural gas triethylene glycol dehydration column
Само за регистроване кориснике
2011
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The paper deals with the tray-to-tray method for determining the required number of trays in columns with intensive entrainment of liquid when the operating line of the "dry working regime" is not straight and with a small concentration of diffusing component in gas. Presented calculations show that the number of transfer units for gas and liquid should be calculated using the AIChE method accompanied with longitudinal mixing according to Gilbert properly transformed for case of diffusion through stagnant film. The suggested method can be applied for TEG dehydration absorbers-columns for dehydration of natural gas using triethylene glycol with system factor SF = 0.5.
Кључне речи:
Unit operations / Natural gas / Diffusion / Dehydration / Computation / AbsorptionИзвор:
Chemical Engineering Research & Design, 2011, 89, 6A, 561-572Издавач:
- Elsevier, Amsterdam
DOI: 10.1016/j.cherd.2010.08.012
ISSN: 0263-8762
WoS: 000292065700001
Scopus: 2-s2.0-79956303210
Институција/група
Inovacioni centarTY - JOUR AU - Jaćimović, Branislav M. AU - Genić, Srbislav AU - Đorđević, Dimitrije R. AU - Budimir, Nikola AU - Jarić, Marko PY - 2011 UR - https://machinery.mas.bg.ac.rs/handle/123456789/1223 AB - The paper deals with the tray-to-tray method for determining the required number of trays in columns with intensive entrainment of liquid when the operating line of the "dry working regime" is not straight and with a small concentration of diffusing component in gas. Presented calculations show that the number of transfer units for gas and liquid should be calculated using the AIChE method accompanied with longitudinal mixing according to Gilbert properly transformed for case of diffusion through stagnant film. The suggested method can be applied for TEG dehydration absorbers-columns for dehydration of natural gas using triethylene glycol with system factor SF = 0.5. PB - Elsevier, Amsterdam T2 - Chemical Engineering Research & Design T1 - Estimation of the number of trays for natural gas triethylene glycol dehydration column EP - 572 IS - 6A SP - 561 VL - 89 DO - 10.1016/j.cherd.2010.08.012 ER -
@article{ author = "Jaćimović, Branislav M. and Genić, Srbislav and Đorđević, Dimitrije R. and Budimir, Nikola and Jarić, Marko", year = "2011", abstract = "The paper deals with the tray-to-tray method for determining the required number of trays in columns with intensive entrainment of liquid when the operating line of the "dry working regime" is not straight and with a small concentration of diffusing component in gas. Presented calculations show that the number of transfer units for gas and liquid should be calculated using the AIChE method accompanied with longitudinal mixing according to Gilbert properly transformed for case of diffusion through stagnant film. The suggested method can be applied for TEG dehydration absorbers-columns for dehydration of natural gas using triethylene glycol with system factor SF = 0.5.", publisher = "Elsevier, Amsterdam", journal = "Chemical Engineering Research & Design", title = "Estimation of the number of trays for natural gas triethylene glycol dehydration column", pages = "572-561", number = "6A", volume = "89", doi = "10.1016/j.cherd.2010.08.012" }
Jaćimović, B. M., Genić, S., Đorđević, D. R., Budimir, N.,& Jarić, M.. (2011). Estimation of the number of trays for natural gas triethylene glycol dehydration column. in Chemical Engineering Research & Design Elsevier, Amsterdam., 89(6A), 561-572. https://doi.org/10.1016/j.cherd.2010.08.012
Jaćimović BM, Genić S, Đorđević DR, Budimir N, Jarić M. Estimation of the number of trays for natural gas triethylene glycol dehydration column. in Chemical Engineering Research & Design. 2011;89(6A):561-572. doi:10.1016/j.cherd.2010.08.012 .
Jaćimović, Branislav M., Genić, Srbislav, Đorđević, Dimitrije R., Budimir, Nikola, Jarić, Marko, "Estimation of the number of trays for natural gas triethylene glycol dehydration column" in Chemical Engineering Research & Design, 89, no. 6A (2011):561-572, https://doi.org/10.1016/j.cherd.2010.08.012 . .