A state space method for the design of turbine governors in hydro power plants with Kaplan turbines is presented. The design is based on the suboptimal regulator problem solved by the use of projective controls. A design procedure that permits the design of multivariable static and low-order dynamic hydroturbine governors is proposed. It provides an organized way of choosing the governor structure and the tuning of its parameters. A case study is presented to illustrate the proposed design method and to demonstrate the extensive applicability of the suboptimal solution and its merits as compared to conventional governors.
Извор:
IEEE Transactions on Energy Conversion, 1991, 6, 3, 438-444Колекције
Институција/група
Mašinski fakultetTY - JOUR AU - Arnautović, D.B. AU - Škatarić, Dobrila PY - 1991 UR - https://machinery.mas.bg.ac.rs/handle/123456789/115 AB - A state space method for the design of turbine governors in hydro power plants with Kaplan turbines is presented. The design is based on the suboptimal regulator problem solved by the use of projective controls. A design procedure that permits the design of multivariable static and low-order dynamic hydroturbine governors is proposed. It provides an organized way of choosing the governor structure and the tuning of its parameters. A case study is presented to illustrate the proposed design method and to demonstrate the extensive applicability of the suboptimal solution and its merits as compared to conventional governors. T2 - IEEE Transactions on Energy Conversion T1 - Suboptimal design of hydroturbine governors EP - 444 IS - 3 SP - 438 VL - 6 DO - 10.1109/60.84319 ER -
@article{ author = "Arnautović, D.B. and Škatarić, Dobrila", year = "1991", abstract = "A state space method for the design of turbine governors in hydro power plants with Kaplan turbines is presented. The design is based on the suboptimal regulator problem solved by the use of projective controls. A design procedure that permits the design of multivariable static and low-order dynamic hydroturbine governors is proposed. It provides an organized way of choosing the governor structure and the tuning of its parameters. A case study is presented to illustrate the proposed design method and to demonstrate the extensive applicability of the suboptimal solution and its merits as compared to conventional governors.", journal = "IEEE Transactions on Energy Conversion", title = "Suboptimal design of hydroturbine governors", pages = "444-438", number = "3", volume = "6", doi = "10.1109/60.84319" }
Arnautović, D.B.,& Škatarić, D.. (1991). Suboptimal design of hydroturbine governors. in IEEE Transactions on Energy Conversion, 6(3), 438-444. https://doi.org/10.1109/60.84319
Arnautović D, Škatarić D. Suboptimal design of hydroturbine governors. in IEEE Transactions on Energy Conversion. 1991;6(3):438-444. doi:10.1109/60.84319 .
Arnautović, D.B., Škatarić, Dobrila, "Suboptimal design of hydroturbine governors" in IEEE Transactions on Energy Conversion, 6, no. 3 (1991):438-444, https://doi.org/10.1109/60.84319 . .