Opto-Magnetic Method for Epstein - Barr Virus and Cytomegalovirus Detection in Blood Plasma Samples
Апстракт
Motivated by characterization of paramagnetic materials (Al, Mn and Ti) and diamagnetic materials (Cu, C and Zn) by opto-magnetic method that is based on light-matter interaction using digital imaging, we present results of Epstein Barr virus (EBV) and cytomegalovirus (CMV) detection in blood plasma. To investigate light-blood plasma interaction we use wavelength difference of diffuse white light and reflected polarized light in red and blue channels of digital images (opto-magnetic method). Digital images of samples are analyzed by spectral convolution algorithm for light-matter interaction analysis. Since opto-magnetic method can detect very small difference between normal and pathological tissue states it is advantageous in comparison with classical methods. Especially it is important for early detection of suspicious tissue states and detection of viral infection presence in plasma. We compared our results with results of standard biomedical test for EBV and CVM, as a reference, an...d found out for group of 40 samples significant correlation of 93. 6%.
Извор:
Acta Physica Polonica A, 2010, 117, 5, 782-785Издавач:
- Polish Acad Sciences Inst Physics, Warsaw
Финансирање / пројекти:
- Развој метода и техника за карактеризацију биоматеријала, биомолекула и ткива помоћу Наноскопа и биоимпенданце (RS-MESTD-MPN2006-2010-19056)
DOI: 10.12693/APhysPolA.117.782
ISSN: 0587-4246
WoS: 000278221700014
Scopus: 2-s2.0-77952702381
Колекције
Институција/група
Mašinski fakultetTY - JOUR AU - Papić-Obradović, Milena AU - Kojić, Dušan AU - Matija, Lidija PY - 2010 UR - https://machinery.mas.bg.ac.rs/handle/123456789/1055 AB - Motivated by characterization of paramagnetic materials (Al, Mn and Ti) and diamagnetic materials (Cu, C and Zn) by opto-magnetic method that is based on light-matter interaction using digital imaging, we present results of Epstein Barr virus (EBV) and cytomegalovirus (CMV) detection in blood plasma. To investigate light-blood plasma interaction we use wavelength difference of diffuse white light and reflected polarized light in red and blue channels of digital images (opto-magnetic method). Digital images of samples are analyzed by spectral convolution algorithm for light-matter interaction analysis. Since opto-magnetic method can detect very small difference between normal and pathological tissue states it is advantageous in comparison with classical methods. Especially it is important for early detection of suspicious tissue states and detection of viral infection presence in plasma. We compared our results with results of standard biomedical test for EBV and CVM, as a reference, and found out for group of 40 samples significant correlation of 93. 6%. PB - Polish Acad Sciences Inst Physics, Warsaw T2 - Acta Physica Polonica A T1 - Opto-Magnetic Method for Epstein - Barr Virus and Cytomegalovirus Detection in Blood Plasma Samples EP - 785 IS - 5 SP - 782 VL - 117 DO - 10.12693/APhysPolA.117.782 ER -
@article{ author = "Papić-Obradović, Milena and Kojić, Dušan and Matija, Lidija", year = "2010", abstract = "Motivated by characterization of paramagnetic materials (Al, Mn and Ti) and diamagnetic materials (Cu, C and Zn) by opto-magnetic method that is based on light-matter interaction using digital imaging, we present results of Epstein Barr virus (EBV) and cytomegalovirus (CMV) detection in blood plasma. To investigate light-blood plasma interaction we use wavelength difference of diffuse white light and reflected polarized light in red and blue channels of digital images (opto-magnetic method). Digital images of samples are analyzed by spectral convolution algorithm for light-matter interaction analysis. Since opto-magnetic method can detect very small difference between normal and pathological tissue states it is advantageous in comparison with classical methods. Especially it is important for early detection of suspicious tissue states and detection of viral infection presence in plasma. We compared our results with results of standard biomedical test for EBV and CVM, as a reference, and found out for group of 40 samples significant correlation of 93. 6%.", publisher = "Polish Acad Sciences Inst Physics, Warsaw", journal = "Acta Physica Polonica A", title = "Opto-Magnetic Method for Epstein - Barr Virus and Cytomegalovirus Detection in Blood Plasma Samples", pages = "785-782", number = "5", volume = "117", doi = "10.12693/APhysPolA.117.782" }
Papić-Obradović, M., Kojić, D.,& Matija, L.. (2010). Opto-Magnetic Method for Epstein - Barr Virus and Cytomegalovirus Detection in Blood Plasma Samples. in Acta Physica Polonica A Polish Acad Sciences Inst Physics, Warsaw., 117(5), 782-785. https://doi.org/10.12693/APhysPolA.117.782
Papić-Obradović M, Kojić D, Matija L. Opto-Magnetic Method for Epstein - Barr Virus and Cytomegalovirus Detection in Blood Plasma Samples. in Acta Physica Polonica A. 2010;117(5):782-785. doi:10.12693/APhysPolA.117.782 .
Papić-Obradović, Milena, Kojić, Dušan, Matija, Lidija, "Opto-Magnetic Method for Epstein - Barr Virus and Cytomegalovirus Detection in Blood Plasma Samples" in Acta Physica Polonica A, 117, no. 5 (2010):782-785, https://doi.org/10.12693/APhysPolA.117.782 . .