Direct-contact condensation heat transfer on downcommerless trays for steam-water system
Abstract
The paper deals with some of the results obtained during experimental research of the direct-contact condensation in cascade column. Downcommerless trays were used to obtain contact between water and steam in DN 300 column and experimental work included 198 runs at atmospheric pressure. Since no equation for the intensity of heat transfer was found in the open literature, original equation was established in the following form NTUL = f(F-LG) where NTUL is number of transfer units for liquid phase and F-LG is two phase kinetic energy parameter.
Keywords:
number of transfer units / kinetic energy parameter / heat transfer / downcommerless tray / direct-contact condensationSource:
International Journal of Heat and Mass Transfer, 2006, 49, 7-8, 1225-1230Publisher:
- Pergamon-Elsevier Science Ltd, Oxford
DOI: 10.1016/j.ijheatmasstransfer.2005.10.003
ISSN: 0017-9310
WoS: 000236121000003
Scopus: 2-s2.0-33144467122
Collections
Institution/Community
Mašinski fakultetTY - JOUR AU - Genić, Srbislav PY - 2006 UR - https://machinery.mas.bg.ac.rs/handle/123456789/584 AB - The paper deals with some of the results obtained during experimental research of the direct-contact condensation in cascade column. Downcommerless trays were used to obtain contact between water and steam in DN 300 column and experimental work included 198 runs at atmospheric pressure. Since no equation for the intensity of heat transfer was found in the open literature, original equation was established in the following form NTUL = f(F-LG) where NTUL is number of transfer units for liquid phase and F-LG is two phase kinetic energy parameter. PB - Pergamon-Elsevier Science Ltd, Oxford T2 - International Journal of Heat and Mass Transfer T1 - Direct-contact condensation heat transfer on downcommerless trays for steam-water system EP - 1230 IS - 7-8 SP - 1225 VL - 49 DO - 10.1016/j.ijheatmasstransfer.2005.10.003 ER -
@article{ author = "Genić, Srbislav", year = "2006", abstract = "The paper deals with some of the results obtained during experimental research of the direct-contact condensation in cascade column. Downcommerless trays were used to obtain contact between water and steam in DN 300 column and experimental work included 198 runs at atmospheric pressure. Since no equation for the intensity of heat transfer was found in the open literature, original equation was established in the following form NTUL = f(F-LG) where NTUL is number of transfer units for liquid phase and F-LG is two phase kinetic energy parameter.", publisher = "Pergamon-Elsevier Science Ltd, Oxford", journal = "International Journal of Heat and Mass Transfer", title = "Direct-contact condensation heat transfer on downcommerless trays for steam-water system", pages = "1230-1225", number = "7-8", volume = "49", doi = "10.1016/j.ijheatmasstransfer.2005.10.003" }
Genić, S.. (2006). Direct-contact condensation heat transfer on downcommerless trays for steam-water system. in International Journal of Heat and Mass Transfer Pergamon-Elsevier Science Ltd, Oxford., 49(7-8), 1225-1230. https://doi.org/10.1016/j.ijheatmasstransfer.2005.10.003
Genić S. Direct-contact condensation heat transfer on downcommerless trays for steam-water system. in International Journal of Heat and Mass Transfer. 2006;49(7-8):1225-1230. doi:10.1016/j.ijheatmasstransfer.2005.10.003 .
Genić, Srbislav, "Direct-contact condensation heat transfer on downcommerless trays for steam-water system" in International Journal of Heat and Mass Transfer, 49, no. 7-8 (2006):1225-1230, https://doi.org/10.1016/j.ijheatmasstransfer.2005.10.003 . .