GROUND SOURCE HEAT PUMP OPERATION ANALYSIS
Konferencijski prilog (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
The paper analyzes the influence of different parameters on the effective Coefficient of Performance (COP) of a ground source heat pump. Heat pump located in the Laboratory for Thermal Science Engineering at the Faculty of Mechanical Engineering in Belgrade is adopted for model. Since the change in soil temperature more or less depends on the change in air temperature, the average monthly air temperatures for the considered heating seasons 2014 ÷ 2018 were used in the calculation. The model enables the analysis of various parameters on performance of heat pump, such as the change of the soil temperature, as well as the change of the return water temperature from the heating system.
Ključne reči:
ground source heat pump / COP / R290Izvor:
Zbornik 52. Međunarodnog kongresa o KGH, 2021Izdavač:
- Beograd: SMEITS
Kolekcije
Institucija/grupa
Mašinski fakultetTY - CONF AU - Cvetković, Marijana AU - Milovančević, Uroš AU - Otović, Milena PY - 2021 UR - https://machinery.mas.bg.ac.rs/handle/123456789/5533 AB - The paper analyzes the influence of different parameters on the effective Coefficient of Performance (COP) of a ground source heat pump. Heat pump located in the Laboratory for Thermal Science Engineering at the Faculty of Mechanical Engineering in Belgrade is adopted for model. Since the change in soil temperature more or less depends on the change in air temperature, the average monthly air temperatures for the considered heating seasons 2014 ÷ 2018 were used in the calculation. The model enables the analysis of various parameters on performance of heat pump, such as the change of the soil temperature, as well as the change of the return water temperature from the heating system. PB - Beograd: SMEITS C3 - Zbornik 52. Međunarodnog kongresa o KGH T1 - GROUND SOURCE HEAT PUMP OPERATION ANALYSIS UR - https://hdl.handle.net/21.15107/rcub_machinery_5533 ER -
@conference{ author = "Cvetković, Marijana and Milovančević, Uroš and Otović, Milena", year = "2021", abstract = "The paper analyzes the influence of different parameters on the effective Coefficient of Performance (COP) of a ground source heat pump. Heat pump located in the Laboratory for Thermal Science Engineering at the Faculty of Mechanical Engineering in Belgrade is adopted for model. Since the change in soil temperature more or less depends on the change in air temperature, the average monthly air temperatures for the considered heating seasons 2014 ÷ 2018 were used in the calculation. The model enables the analysis of various parameters on performance of heat pump, such as the change of the soil temperature, as well as the change of the return water temperature from the heating system.", publisher = "Beograd: SMEITS", journal = "Zbornik 52. Međunarodnog kongresa o KGH", title = "GROUND SOURCE HEAT PUMP OPERATION ANALYSIS", url = "https://hdl.handle.net/21.15107/rcub_machinery_5533" }
Cvetković, M., Milovančević, U.,& Otović, M.. (2021). GROUND SOURCE HEAT PUMP OPERATION ANALYSIS. in Zbornik 52. Međunarodnog kongresa o KGH Beograd: SMEITS.. https://hdl.handle.net/21.15107/rcub_machinery_5533
Cvetković M, Milovančević U, Otović M. GROUND SOURCE HEAT PUMP OPERATION ANALYSIS. in Zbornik 52. Međunarodnog kongresa o KGH. 2021;. https://hdl.handle.net/21.15107/rcub_machinery_5533 .
Cvetković, Marijana, Milovančević, Uroš, Otović, Milena, "GROUND SOURCE HEAT PUMP OPERATION ANALYSIS" in Zbornik 52. Međunarodnog kongresa o KGH (2021), https://hdl.handle.net/21.15107/rcub_machinery_5533 .