Search
Now showing items 31-40 of 616
Influence of crack length on ductile fracture initiation in welded joints with one and two weld metals
(Trans Tech Publications Ltd, Durnten-Zurich, 2011)
Among various micromechanical models for ductile fracture analysis using local approach, those based on the Gurson plastic flow criterion have been intensively developed in the past three decades. However, their application ...
Weld metal tensile strength determined by testing flat micro tensile and round tensile specimens
(Scientific Society for Mechanical Engineering, 2011)
Experimental investigation of temperature and strain-rate behaviour of Ti3Al-Nb alloy
(Scientific Society for Mechanical Engineering, 2011)
API J55 Steel Casing Pipe with an Initial Surface Crack under Internal Pressure - Determination of Fracture Parameters
(Trans Tech Publications Ltd, Durnten-Zurich, 2012)
Seam casing pipe used in an oil drilling rig, manufactured by high frequency (HF) contact welding of API J55 steel, is tested. The influence of an initial defect (machined surface crack) is analysed, by performing pressure ...
Experimental analysis of artificial hip implant made of titanium alloy
(University of Belgrade, 2012)
Controller area network based monitoring of vehicle's mechatronics system
(SISY 2011 - 9th International Symposium on Intelligent Systems and Informatics, Proceedings, 2011)
The implementation of various electronic subsystems in different kinds of on-road and off-road vehicles is constantly expanding. Accordingly, the new vehicles, instead of being mechanical systems, become advanced mechatronics ...
Project Management Software for Distributed Industrial Companies
(Springer-Verlag Berlin, Berlin, 2010)
This paper gives an overview of the development of a new software solution for project management, intended mainly to use in industrial environment. The main concern of the proposed solution is application in everyday ...
Procena integriteta konstrukcije implanta veštačkog kuka izrađenog od višefazne Co-Cr legure / Structural integrity assessment of hip implant made of cobalt-chromium multiphase alloy
(Institut za ispitivanje materijala, Beograd, 2010)
Rad prikazuje analizu parametara mehanike loma višefazne Co-Cr legure, koja se koristi kao materijal za implant kod ugradnje veštačkog kuka. Konstrukcijski parametri koje bi trebalo uzeti u obzir tokom projektovanja implanta ...
3D Experimental optical analysis of titanium alloys for biomedical applications
(INES 2011 - 15th International Conference on Intelligent Engineering Systems, Proceedings, 2011)
In this paper is presented an example of experimental analysis of biomaterials based on optical measurement methodology. GOM optical system and Aramis software were used to perform 3D experimental optical analysis of ...
Work analysis of the energy steam boiler evaporator with sliding pressure of 350 MW block
(Nis University, 2011)
Within Electric Power Utility of Serbia 1991. a thermal power plant "Kostolac B", power 2x350 MW started. Based on the examination of steam boiler pipe system, it is confirmed that it is in "bad" shape. It's most jeopardized ...