Galatanu, Teofil

Link to this page

Authority KeyName Variants
2e8bd647-771f-407b-a1e1-879b1bec2f61
  • Galatanu, Teofil (2)
Projects
No records found.

Author's Bibliography

Butt welded joints assessment after fire exposure

Radu, Dorin; Galatanu, Teofil; Sedmak, Simon

(Pergamon-Elsevier Science Ltd, Oxford, 2019)

TY  - JOUR
AU  - Radu, Dorin
AU  - Galatanu, Teofil
AU  - Sedmak, Simon
PY  - 2019
UR  - https://machinery.mas.bg.ac.rs/handle/123456789/3075
AB  - The need of in service life of a steel structure after being exposed to fire raises the problem of strengthening or replacement of some structural elements. In many cases, after structural safety assessment, fire exposed steel structures can be reused. Establishing the post-fire residual capacity of the structure has a major importance in overall assessment process. The paper presents a study for fire behavior of the butt-welded joints subjected to low cycle fatigue loading, taken into account the post fire conditions and the possibility of welding strengthening. There is presented a case study - a building structural element subjected to dynamic loading after fire exposure. For the in case study, post fire investigations revealed several welding flaws including welding surface type flaws. An assessment was needed in order to determine the structural integrity and life assessment of some structural elements. From the fracture mechanics point of view, a Failure Assessment Diagrams FAD - level 2 procedure was applied in order to determine the in service safety of the structure. Several flaws types were assessed and conclusions were taken. The results can be used for damage assessment and strengthening technique of post fire steel structures.
PB  - Pergamon-Elsevier Science Ltd, Oxford
T2  - Engineering Failure Analysis
T1  - Butt welded joints assessment after fire exposure
VL  - 106
DO  - 10.1016/j.engfailanal.2019.08.010
ER  - 
@article{
author = "Radu, Dorin and Galatanu, Teofil and Sedmak, Simon",
year = "2019",
abstract = "The need of in service life of a steel structure after being exposed to fire raises the problem of strengthening or replacement of some structural elements. In many cases, after structural safety assessment, fire exposed steel structures can be reused. Establishing the post-fire residual capacity of the structure has a major importance in overall assessment process. The paper presents a study for fire behavior of the butt-welded joints subjected to low cycle fatigue loading, taken into account the post fire conditions and the possibility of welding strengthening. There is presented a case study - a building structural element subjected to dynamic loading after fire exposure. For the in case study, post fire investigations revealed several welding flaws including welding surface type flaws. An assessment was needed in order to determine the structural integrity and life assessment of some structural elements. From the fracture mechanics point of view, a Failure Assessment Diagrams FAD - level 2 procedure was applied in order to determine the in service safety of the structure. Several flaws types were assessed and conclusions were taken. The results can be used for damage assessment and strengthening technique of post fire steel structures.",
publisher = "Pergamon-Elsevier Science Ltd, Oxford",
journal = "Engineering Failure Analysis",
title = "Butt welded joints assessment after fire exposure",
volume = "106",
doi = "10.1016/j.engfailanal.2019.08.010"
}
Radu, D., Galatanu, T.,& Sedmak, S.. (2019). Butt welded joints assessment after fire exposure. in Engineering Failure Analysis
Pergamon-Elsevier Science Ltd, Oxford., 106.
https://doi.org/10.1016/j.engfailanal.2019.08.010
Radu D, Galatanu T, Sedmak S. Butt welded joints assessment after fire exposure. in Engineering Failure Analysis. 2019;106.
doi:10.1016/j.engfailanal.2019.08.010 .
Radu, Dorin, Galatanu, Teofil, Sedmak, Simon, "Butt welded joints assessment after fire exposure" in Engineering Failure Analysis, 106 (2019),
https://doi.org/10.1016/j.engfailanal.2019.08.010 . .
6
6

Structural integrity of butt welded connection after fire exposure

Radu, Dorin; Galatanu, Teofil; Sedmak, Simon

(Elsevier Science Bv, Amsterdam, 2018)

TY  - CONF
AU  - Radu, Dorin
AU  - Galatanu, Teofil
AU  - Sedmak, Simon
PY  - 2018
UR  - https://machinery.mas.bg.ac.rs/handle/123456789/2841
AB  - The paper presents a study for fire behavior of the butt-welded joints subjected to low cycle fatigue loading, taken into account the post fire conditions and the possibility of welding strengthening. The need of in service life of a steel structure after being exposed to fire raises the problem of strengthening or replacement of some structural elements. There is presented a case study a building structural element subjected to dynamic loading after fire exposure [1]. For the in case study, post fire investigations revealed several welding flaws including crack type flaws. An assessment was needed in order to determine the structural integrity and life assessment of some structural elements. From the fracture mechanics point of view, a Failure Assessment Diagrams level 2 - FAD 2 procedure was applied in order to determine the in service safety of the structure. Several flaws types were assessed and conclusions were taken. The results can be used for damage assessment and strengthening technique of post fire steel structures.
PB  - Elsevier Science Bv, Amsterdam
C3  - Procedia Structural Integrity - ECF22 - Loading and environmental effects on structural integrity
T1  - Structural integrity of butt welded connection after fire exposure
EP  - 1087
SP  - 1082
VL  - 13
DO  - 10.1016/j.prostr.2018.12.227
ER  - 
@conference{
author = "Radu, Dorin and Galatanu, Teofil and Sedmak, Simon",
year = "2018",
abstract = "The paper presents a study for fire behavior of the butt-welded joints subjected to low cycle fatigue loading, taken into account the post fire conditions and the possibility of welding strengthening. The need of in service life of a steel structure after being exposed to fire raises the problem of strengthening or replacement of some structural elements. There is presented a case study a building structural element subjected to dynamic loading after fire exposure [1]. For the in case study, post fire investigations revealed several welding flaws including crack type flaws. An assessment was needed in order to determine the structural integrity and life assessment of some structural elements. From the fracture mechanics point of view, a Failure Assessment Diagrams level 2 - FAD 2 procedure was applied in order to determine the in service safety of the structure. Several flaws types were assessed and conclusions were taken. The results can be used for damage assessment and strengthening technique of post fire steel structures.",
publisher = "Elsevier Science Bv, Amsterdam",
journal = "Procedia Structural Integrity - ECF22 - Loading and environmental effects on structural integrity",
title = "Structural integrity of butt welded connection after fire exposure",
pages = "1087-1082",
volume = "13",
doi = "10.1016/j.prostr.2018.12.227"
}
Radu, D., Galatanu, T.,& Sedmak, S.. (2018). Structural integrity of butt welded connection after fire exposure. in Procedia Structural Integrity - ECF22 - Loading and environmental effects on structural integrity
Elsevier Science Bv, Amsterdam., 13, 1082-1087.
https://doi.org/10.1016/j.prostr.2018.12.227
Radu D, Galatanu T, Sedmak S. Structural integrity of butt welded connection after fire exposure. in Procedia Structural Integrity - ECF22 - Loading and environmental effects on structural integrity. 2018;13:1082-1087.
doi:10.1016/j.prostr.2018.12.227 .
Radu, Dorin, Galatanu, Teofil, Sedmak, Simon, "Structural integrity of butt welded connection after fire exposure" in Procedia Structural Integrity - ECF22 - Loading and environmental effects on structural integrity, 13 (2018):1082-1087,
https://doi.org/10.1016/j.prostr.2018.12.227 . .
3
3